Water isotope ratio (δ2H and δ18O) measurements in atmospheric moisture using an optical feedback cavity enhanced absorption laser spectrometer

Abstract: [1] Water vapor isotopes represent an innovative and excellent tool for understanding complex mechanisms in the atmospheric water cycle over different time scales, and they can be used for a variety of applications in the fields of paleoclimatology, hydrology, oceanography, and ecology. We use an ultrasensitive near-infrared spectrometer, originally designed for use on airborne platforms in the upper troposphere and lower stratosphere, to measure the water deuterium and oxygen-18 isotope ratios in situ, in gro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
28
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 41 publications
(29 citation statements)
references
References 40 publications
1
28
0
Order By: Relevance
“…Successful inter-comparison of OF-CEAS analyzers and mass spectrometer [48] as well as gas chromatograph have been reported [49]. A real-time numerical fit of the measured absorption spectra enables the selective determination of the concentrations of all compounds that possess absorption lines in the selected spectral window.…”
Section: Optical Feedback Cavity-enhanced Absorption Spectroscopymentioning
confidence: 99%
“…Successful inter-comparison of OF-CEAS analyzers and mass spectrometer [48] as well as gas chromatograph have been reported [49]. A real-time numerical fit of the measured absorption spectra enables the selective determination of the concentrations of all compounds that possess absorption lines in the selected spectral window.…”
Section: Optical Feedback Cavity-enhanced Absorption Spectroscopymentioning
confidence: 99%
“…A mass balance of soil water compared to the total amount of vapor at saturation indicates that Rayleigh effects are far below the analytical precision of 0.15-0.25 ‰ for δ 18 O and of 1.0-1.5 ‰ for δ 2 H VSMOW, and do not affect the results significantly. Analysis was completed using Picarro cavity ring-down laser spectrometry (Picarro Inc., Santa Clara, California) (Iannone et al, 2010) for water isotopes based on principles of tunable diode laser spectrometry (Gianfrani et al, 2003;Kerstel and Gianfrani, 2008;Gupta et al, 2009). …”
Section: Analysis Of Soil Water Isotopic Compositionmentioning
confidence: 99%
“…Except for some work based on cold trap sampling (Jacob and Sonntag, 1991;Williams et al, 2004;Angert et al, 2008), there are to our knowledge only three high time-resolution studies published from European sites (Iannone et al, 2010;Kurita et al, 2012;Aemisegger et al, 2014) and none at all treating Mediterranean areas. In addition, there is a need for dual tracer databases, in order to use the deuterium excess signal (d = δD − 8 × δ 18 O; Dansgaard, 1964) as an additional indicator of atmospheric processes.…”
Section: Introductionmentioning
confidence: 99%