Waterproofing EMG Instrumentation

Abstract: While still experimental, measurement of external uterine electromyographic (EMG) activity is a more sensitive and noninvasive method for measuring uterine contractility in human labor than the methods currently used in clinical practice. Hydrotherapy is purported to improve contractility in labor, yet there have been no reports of abdominal uterine EMG activity measured during immersion. To test telemetric EMG equipment and different waterproofing techniques under dry and immersed conditions, the authors reco… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
2
1

Year Published

2008
2008
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 17 publications
0
12
2
1
Order By: Relevance
“…For example, Benfield et al (2007) noted distinct visual aberrations in sEMG baseline stability when surface electrodes were exposed to water. Consequently, prior to water immersion, each set of electrodes ( Fig.…”
Section: Electrode Waterproofingmentioning
confidence: 97%
See 3 more Smart Citations
“…For example, Benfield et al (2007) noted distinct visual aberrations in sEMG baseline stability when surface electrodes were exposed to water. Consequently, prior to water immersion, each set of electrodes ( Fig.…”
Section: Electrode Waterproofingmentioning
confidence: 97%
“…Holes were cut in the center of the OpSite™ to access the electrode snaps. The covered electrodes and area around each electrode site were sprayed with a waterproof adhesive (Nexcare™ Spray Liquid Bandage, 3M, St. Paul, MN) as described by Benfield et al (2007). After attaching the electrode wires ( Fig.…”
Section: Electrode Waterproofingmentioning
confidence: 99%
See 2 more Smart Citations
“…No entanto, recentemente, as pesquisas de Rainoldi et al (26) e Veneziano et al (30) mostraram que a amplitude do sinal EMG pode ser semelhante entre os meios aquático e terrestre, quando alguns fatores são controlados, tais como tipo de protocolo, temperatura da pele, que reflete a temperatura muscular e utilização de isolamento adequado sobre os eletrodos. De acordo com o estudo de Benfield et al (4) e Rainoldi et al (26) , a utilização de isolamento sobre os eletrodos de superfície para as coletas realizadas no meio líquido é de fundamental importância, uma vez que o movimento da água sobre os eletrodos pode introduzir artefatos de baixas freqüências no sinal EMG. Logo, a utilização de adesivos, que impedem a entrada e contato da água com os eletrodos, é a melhor solução para manter inalterada a freqüência e a amplitude do sinal EMG.…”
Section: Introductionunclassified