2022
DOI: 10.3390/electronics11040591
|View full text |Cite
|
Sign up to set email alerts
|

Waveform and Spectral Characteristics of Supraharmonic Unsymmetrical Conducted EMI of Switched-Mode Power Supplies

Abstract: Switched-mode power supplies (SMPSs) are a relevant and widespread source of unsymmetrical conducted emissions, as they feed various electrical appliances and information technology equipment in office and residential contexts and, despite their low power rating, the limits are the same as those of larger equipment. Given the peculiar emission waveform (mixing impulsive components and switching components), assessment should be carried out with care to select parameters that guarantee both the detection of the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(1 citation statement)
references
References 12 publications
0
1
0
Order By: Relevance
“…With the extensive use of PFC, low-frequency harmonic distortion problems have been largely mitigated, shifting distortion to higher frequency, as a byproduct of waveform manipulation to achieve PFC and mixing with the distortion of the DC-DC converter downstream for DC bus regulation. The impact of PFC on the AC grid materializes as typical pulse width modulation bands for active rectifier implementations, or oscillating pulses, named zero-crossing oscillations in [36]: such pulses have frequency occupation in approximately the 2-10 kHz range [37,38] and can cause excessive stress and interference in equipment and components, with consequential malfunction and damage [36].…”
mentioning
confidence: 99%
“…With the extensive use of PFC, low-frequency harmonic distortion problems have been largely mitigated, shifting distortion to higher frequency, as a byproduct of waveform manipulation to achieve PFC and mixing with the distortion of the DC-DC converter downstream for DC bus regulation. The impact of PFC on the AC grid materializes as typical pulse width modulation bands for active rectifier implementations, or oscillating pulses, named zero-crossing oscillations in [36]: such pulses have frequency occupation in approximately the 2-10 kHz range [37,38] and can cause excessive stress and interference in equipment and components, with consequential malfunction and damage [36].…”
mentioning
confidence: 99%