2022
DOI: 10.1186/s10033-022-00695-3
|View full text |Cite
|
Sign up to set email alerts
|

Wear Characteristics of the Nuclear Control Rod Drive Mechanism (CRDM) Movable Latch Serviced in High Temperature Water

Abstract: The current research of nuclear control rod drive mechanism (CRDM) movable latch only makes a simple measurement of wear mass. The wear volume and difference in various claw surfaces are ignored and the degradation mechanism of each claw surface is not clear. In this paper, a detailed degradation analysis was carried out on each claw surface of movable latch combined with wear result and worn morphology. Results indicate that the boundary of carbide is preferred for corrosion because carbide presents a nobler … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…Refs. [11][12][13][14] introduce the research contents related to fault analysis and detection of control rod drive mechanism in nuclear reactors in recent years. Aiming at the weld crack fault of the drive mechanism, scholars designed a decimeter size cable-driven elastic spine worm robot [11], which has high adaptability in the weld crack detection between the reactor pressure vessel (RPV) and the CRDM.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Refs. [11][12][13][14] introduce the research contents related to fault analysis and detection of control rod drive mechanism in nuclear reactors in recent years. Aiming at the weld crack fault of the drive mechanism, scholars designed a decimeter size cable-driven elastic spine worm robot [11], which has high adaptability in the weld crack detection between the reactor pressure vessel (RPV) and the CRDM.…”
Section: Introductionmentioning
confidence: 99%
“…The experimental results show that this method can effectively eliminate the noise interference and realize the roll state diagnosis. The current research on the movable latch of the nuclear control rod drive mechanism (CRDM) only made a simple measurement of the wear quality, ignored the wear amount and difference of each claw surface, and did not know the degradation mechanism of each claw surface [13]. Combined with the wear results and wear patterns, a detailed degradation analysis was carried out on each claw surface of the movable latch.…”
Section: Introductionmentioning
confidence: 99%