1986
DOI: 10.3109/17453678608994373
|View full text |Cite
|
Sign up to set email alerts
|

Wear of the acetabular socket: Comparison of polyacetat and polyethylene

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
12
0
1

Year Published

1986
1986
2005
2005

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 8 publications
1
12
0
1
Order By: Relevance
“…The cause of loosening is considered to be multifactorial and has been analyzed using several approaches: viz., clinical research on demographic and physiologic variables ( 5 , 9, 38-44), preparation and cementing technique (8,40,(45)(46)(47)(48), prosthetic design, positioning, friction and wear (1,3,5,8,9,(38)(39)(40)(49)(50)(51)(52)(53)(54)(55)(56)(57)(58)(59)(60)(61)(62); biological responses studied in human investigations (63)(64)(65)(66)(67)(68)(69)(70)(71)(72)(73)(74)(75)(76)(77)(78)(79) and in animal experiments (80)(81)(82)…”
Section: Introductionmentioning
confidence: 99%
“…The cause of loosening is considered to be multifactorial and has been analyzed using several approaches: viz., clinical research on demographic and physiologic variables ( 5 , 9, 38-44), preparation and cementing technique (8,40,(45)(46)(47)(48), prosthetic design, positioning, friction and wear (1,3,5,8,9,(38)(39)(40)(49)(50)(51)(52)(53)(54)(55)(56)(57)(58)(59)(60)(61)(62); biological responses studied in human investigations (63)(64)(65)(66)(67)(68)(69)(70)(71)(72)(73)(74)(75)(76)(77)(78)(79) and in animal experiments (80)(81)(82)…”
Section: Introductionmentioning
confidence: 99%
“…30 However, only a few studies have analyzed PA retrievals. [30][31][32][33] Havelin and colleagues 32 measured the surface roughness (R a ) of one retrieved Christiansen prosthesis with a profilometer. One surface profile, shown in Figure 3 of Havelin's article, 32 reported an R a of 0.06 m for the wear surface of the used prosthesis, which falls within the range of 0.028 to 0.075 m measured for the weartested inserts in this study.…”
Section: Discussionmentioning
confidence: 99%
“…Polyacetal can be formed into parts rapidly by injection-moulding, which is faster and cheaper than machining from blocks of polyacetal. It was estimated that more than 10.000 devices containing this material were implanted between 1970 and 1986 (Mathiesen et al 1986). However, by the mid-1980's, several groups of investigators had reported higher failure rates than for other contemporary prostheses and their use was discontinued (Alho et al 1984, Mathiesen et al 1986, Sudmann et al 1983).…”
Section: Historymentioning
confidence: 99%