Abstract: The wear rate on Total Hip Arthroplasty (THA) entails a heavy burden for patients. This becomes more relevant with increased wear risk and its consequences such as osteolysis. In addition, osteolysis has been described in cemented and uncemented acetabular implants, and nowadays, controversy remains as to whether or not to cement the acetabular component. A personalized theoretical study was carried out to investigate which parameters have an influence on wear risk and to determine the best fixation method. Li… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 43 publications
0
4
0
Order By: Relevance
“…Next, only femoral head and acetabular cup components are taken into account. In contrast, considering other components, such as pelvic bone and acetabular shell, results in a more realistic modelling scenario [ 59 ]. In terms of the materials assumption, the present finite element model assumes a purely elastic material, without considering plastic behavior on CoCrMo, Al 2 O 3 , and PCD.…”
Section: Resultsmentioning
confidence: 99%
“…Next, only femoral head and acetabular cup components are taken into account. In contrast, considering other components, such as pelvic bone and acetabular shell, results in a more realistic modelling scenario [ 59 ]. In terms of the materials assumption, the present finite element model assumes a purely elastic material, without considering plastic behavior on CoCrMo, Al 2 O 3 , and PCD.…”
Section: Resultsmentioning
confidence: 99%
“…Ceramic has good friction, wear, and lubrication properties on the ceramic artificial hip joint, and there is no wear particles and osteolysis after hip prosthesis replacement. The fourth-generation ceramic material has become the preferred femoral head prosthesis material for hip replacement due to its hard texture, biological inertia, and low friction coefficient [13,19,20]. Although the finite element analysis model in this experiment can reflect the stress of the femoral head with different materials on the lining, osteolysis caused by interfacial friction and its induced particles is not considered [21,22].…”
Section: Influence Of Different Prosthesis Materials On Finitementioning
confidence: 99%
“…Cemented and uncemented prostheses are two choices of fixation for THA. Although cemented THA could provide relatively better prognosis for elderly patients ( 3 ), increasing early loosening rates have been reported ( 4 , 5 ). Besides, younger patients who underwent cemented THA have exhibited higher risk of revision due to more exercise ( 6 ).…”
Section: Introductionmentioning
confidence: 99%