1999
DOI: 10.1016/s0039-9140(98)00285-9
|View full text |Cite
|
Sign up to set email alerts
|

Wet effluent parallel plate diffusion denuder coupled capillary ion chromatograph for the determination of atmospheric trace gases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 13 publications
0
15
0
Order By: Relevance
“…They found that the simpler construction of PPWD offered better absorption efficiency than the annular denuder. The silicacoated PPWD was also used to measure gaseous nitrous, nitric acids, 8 and atmospheric trace gases 9 and showed good gas absorption efficiency. The operation parameter and gas absorption efficiency of previous studies on silica-coated PPWD is shown in Table 1.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…They found that the simpler construction of PPWD offered better absorption efficiency than the annular denuder. The silicacoated PPWD was also used to measure gaseous nitrous, nitric acids, 8 and atmospheric trace gases 9 and showed good gas absorption efficiency. The operation parameter and gas absorption efficiency of previous studies on silica-coated PPWD is shown in Table 1.…”
Section: Introductionmentioning
confidence: 99%
“…The operation parameter and gas absorption efficiency of previous studies on silica-coated PPWD is shown in Table 1. [7][8][9] Rosman et al 5 used silica-coated denuder described in Simon and Dasgupta [7][8][9] to conduct field measurements. They found that the active surfaces would become unwettable and could not be recovered by washing with solvent when some oily gases were adsorbed on the surface.…”
Section: Introductionmentioning
confidence: 99%
“…Boring et al [79] then coupled a preconcentration column equipped capillary IC system described above to a miniature parallel plate denuder used for collecting soluble gases. They showed that low parts per trillion level detectability of trace ionogenic gases is readily attainable ( Figure 6).…”
Section: Suppressed Ic In Capillary Formatmentioning
confidence: 99%
“…However, they noted that collection efficiency for acetic acid gas fell to 85%, which might reflect sampling loss in the sampling line and uncertainties due to aging of the acetic acid gas permeation source. Boring et al (1999Boring et al ( , 2002 applied larger silica particles (74-127 μm) and larger denuder plates (273 cm 2 per plate) on the WEPPD to detect gaseous acid concentrations (including acetic acid gas) in field environments. Rather than being bonded chemically with the NaOH/Na 2 SiO 3 solution, silica particles were coated onto plates by thermal bonding.…”
Section: Introductionmentioning
confidence: 99%