2015
DOI: 10.1093/jhps/hnv055
|View full text |Cite
|
Sign up to set email alerts
|

What are the current indications for use of radiofrequency devices in Hip arthroscopy? A systematic review: Table I

Abstract: The role of radiofrequency energy (RFE) devices has been minimally studied in hip arthroscopy. The purpose of this study was to determine the role of RFE devices in hip arthroscopy through a systematic review of the literature. We searched the PubMed database using the following Medical Subject Heading terms: hip arthroscopy, hip radiofrequency, thermal capsulorrhaphy, thermal chondroplasty and radiofrequency debridement. Two authors independently reviewed the literature and included articles based on predeter… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 28 publications
0
4
0
Order By: Relevance
“…4,65 Moreover, the risk-benefit ratio of hip arthroscopic radiofrequency device use in soft tissue handling, capsular management, synovial inflammation, and chondral injuries remains unknown. 82…”
Section: Surgical Techniquementioning
confidence: 99%
“…4,65 Moreover, the risk-benefit ratio of hip arthroscopic radiofrequency device use in soft tissue handling, capsular management, synovial inflammation, and chondral injuries remains unknown. 82…”
Section: Surgical Techniquementioning
confidence: 99%
“…If energy is too high it can cause a phenomenon which is similar to Electric Convulsive Therapy (ECT) which can cause patient to be in a stupor state or worst scenario of cardiac complications such as asystole 45) . We do not recommend use of arthroscopic setting use in knee and shoulder to be use in spine 51) . While an energy setting which is too close to low energy radiofrequency ablation may not be efficient in soft tissue dissection in a layer dorsal to ligamentum flavum.…”
Section: Endoscopic Drill and Energy Systemmentioning
confidence: 93%
“…Although adverse events from RF are unusual, potential complications can include infection, bleeding, numbness or dysesthesia, increased pain at the procedural site, deafferentation effect, and Charcot joint neuropathy. Although there is a risk of damaging non-targeted neural tissue and other structures, this can be mitigated by performing the technique under imaging guidance (fluoroscopy, ultrasonography, and computed tomography) ( 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 ).…”
Section: General Conceptsmentioning
confidence: 99%