2013
DOI: 10.1038/jcbfm.2013.31
|View full text |Cite
|
Sign up to set email alerts
|

What Went Wrong? the Flawed Concept of Cerebrospinal Venous Insufficiency

Abstract: In 2006, Zamboni reintroduced the concept that chronic impaired venous outflow of the central nervous system is associated with multiple sclerosis (MS), coining the term of chronic cerebrospinal venous insufficiency (‘CCSVI'). The diagnosis of ‘CCSVI' is based on sonographic criteria, which he found exclusively fulfilled in MS. The concept proposes that chronic venous outflow failure is associated with venous reflux and congestion and leads to iron deposition, thereby inducing neuroinflammation and degeneratio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
58
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(60 citation statements)
references
References 134 publications
(221 reference statements)
2
58
0
Order By: Relevance
“…15 Transcranial color-coded sonography is an imaging method with many advantages (rapid, cheap, realization on patient's bedside), but suffers significantly limiting factors such as operator's skills and experience, head position, respiration, heart rate, external compression, hydration status, as well as factors related to the absence of blinding, and to some technical factors. 16 In turn, PC-MRI, especially using semi-automatic segmentation algorithms, 9 offers operator-independent, rapid, non-invasive; and reproducible quantitative assessment of extracranial and intracranial flows. Moreover, its relevance in venous flow quantification has been demonstrated in healthy subjects in a previous study, 8 and results were validated because they were similar to those of the invasive catheter venography, stated as the gold-standard reference technique.…”
Section: Discussionmentioning
confidence: 99%
“…15 Transcranial color-coded sonography is an imaging method with many advantages (rapid, cheap, realization on patient's bedside), but suffers significantly limiting factors such as operator's skills and experience, head position, respiration, heart rate, external compression, hydration status, as well as factors related to the absence of blinding, and to some technical factors. 16 In turn, PC-MRI, especially using semi-automatic segmentation algorithms, 9 offers operator-independent, rapid, non-invasive; and reproducible quantitative assessment of extracranial and intracranial flows. Moreover, its relevance in venous flow quantification has been demonstrated in healthy subjects in a previous study, 8 and results were validated because they were similar to those of the invasive catheter venography, stated as the gold-standard reference technique.…”
Section: Discussionmentioning
confidence: 99%
“…20 The definition of venous reflux used by Zamboni and colleagues has been challenged because spectral Doppler measurements of duration were not implemented. 21 Furthermore, the 0.88-second threshold used to identify reflux was adopted from a study that examined internal jugular vein valve insufficiency during the Valsalva manoeuvre and was not based on validated methodology.…”
Section: Discussionmentioning
confidence: 99%
“…In fact, there are reports clearly showing that patients are willing to run the risk of lifeendangering side effects from immunosuppressive drugs for MS in order to continue with the treatment 57,58 . Furthermore, thousands of patients with MS worldwide were found to be willing to submit themselves to a vascular surgical procedure to treat their MS for which there was no scientific basis 59 . The evidence arising from these events therefore begs the following questions: Should modifiable factors be so difficult to modify, given that the methods are inexpensive and safe?…”
Section: Discussionmentioning
confidence: 99%