2013
DOI: 10.3791/50263-v
|View full text |Cite
|
Sign up to set email alerts
|

Whole-Body Nanoparticle Aerosol Inhalation Exposures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…Particle characteristics have previously been determined, including primary particle size (21 nm), specic surface area (48.08 m 2 g −1 ), and zeta potential (−56.6 mV). 23,24 Animal model Female Sprague-Dawley (SD) rats were purchased pregnant from Hilltop Laboratories (Scottdale, PA) and housed in an American Association for Accreditation of Laboratory Animal Care (AAALAC) approved facility at West Virginia University (WVU). All animal procedures were performed in accordance with the Guidelines for Care and Use of Laboratory Animals of West Virginia University (WVU) and approved by the Animal Care and Use Committee of WVU.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Particle characteristics have previously been determined, including primary particle size (21 nm), specic surface area (48.08 m 2 g −1 ), and zeta potential (−56.6 mV). 23,24 Animal model Female Sprague-Dawley (SD) rats were purchased pregnant from Hilltop Laboratories (Scottdale, PA) and housed in an American Association for Accreditation of Laboratory Animal Care (AAALAC) approved facility at West Virginia University (WVU). All animal procedures were performed in accordance with the Guidelines for Care and Use of Laboratory Animals of West Virginia University (WVU) and approved by the Animal Care and Use Committee of WVU.…”
Section: Methodsmentioning
confidence: 99%
“…Particle characteristics have previously been determined, including primary particle size (21 nm), specific surface area (48.08 m 2 g −1 ), and zeta potential (−56.6 mV). 23,24…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…[34] These findings are largely based on in vivo studies. [35,36] At present, there are no validated systems for aerosol application of drugs or nanomaterials in a high-throughput format and for the rapid determination of effect thresholds. Such systems would be of great help in the field of occupational hazard potential analysis and in the risk assessment of new materials in the micro-and nanoscale regime, such as cellulose nanocrystals (CNC) for example.…”
Section: Introductionmentioning
confidence: 99%