2016
DOI: 10.1016/j.meddos.2015.06.003
|View full text |Cite
|
Sign up to set email alerts
|

Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
17
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(19 citation statements)
references
References 5 publications
2
17
0
Order By: Relevance
“…In contrast to Fan et al, who were the first group describing a combined sparing approach of the hippocampus and the HT-P area using IMRT, we chose a VMAT approach. For hippocampal sparing during WBRT (without the HT-P area), the use of VMAT was shown to significantly improve dose distribution in terms of target coverage and homogeneity [26][27][28]. In the study of Sood et al, the use of a VMAT-technique also reduced mean and maximum doses to other organs at risk (OAR) such as cochleae and parotid glands [29].…”
Section: Discussionmentioning
confidence: 99%
“…In contrast to Fan et al, who were the first group describing a combined sparing approach of the hippocampus and the HT-P area using IMRT, we chose a VMAT approach. For hippocampal sparing during WBRT (without the HT-P area), the use of VMAT was shown to significantly improve dose distribution in terms of target coverage and homogeneity [26][27][28]. In the study of Sood et al, the use of a VMAT-technique also reduced mean and maximum doses to other organs at risk (OAR) such as cochleae and parotid glands [29].…”
Section: Discussionmentioning
confidence: 99%
“…Although advanced radiotherapy technologies, including IMRT and VMAT, have made it possible to spare the hippocampus during WBRT, delivering HS-WBRT is challenging, owing to the central location of the hippocampus within the brain. Lee et al have previously reported that compared to IMRT, VMAT treatment plans produced a more homogenous dose distribution and decreased the maximum point dose to the target [11]. In their study, non-coplanar arcs were used for VMAT, owing to limitations associated with the angle of the arc, which prevent direct irradiation to the lens and meeting the dose constraint.…”
Section: Discussionmentioning
confidence: 99%
“…Volumetric-modulated arc therapy (VMAT) is an advanced form of IMRT that delivers radiation dose with a 360-degree rotation of the gantry. Previous studies have shown that VMAT has dosimetric outcomes superior to IMRT in HS-WBRT [10,11]. Moreover, Sood et al have reported that VMAT could reduce irradiation dose to the hippocampus and other healthy organs, including the scalp, auditory canals, cochleae, and parotid gland [12].…”
Section: Introductionmentioning
confidence: 99%
“…More recently, volumetric modulated arc therapy (VMAT) has also been examined for HA-WBRT. 8 VMAT showed superior dosimetric performance to IMRT, 9,10 and can practically deliver dose painting in form of simultaneous integrated boost (SIB) 11 to multiple brain metastases, 12,13 along with HA-WBRT. 14,15 Dosimetric quality and efficiency for IMRT and VMAT were further promoted by a recent advancement in inverse planning technology: multi-criteria optimization (MCO).…”
Section: Introductionmentioning
confidence: 99%