2016
DOI: 10.1364/ol.41.001317
|View full text |Cite
|
Sign up to set email alerts
|

Wide-field broadband extreme ultraviolet transmission ptychography using a high-harmonic source

Abstract: High-harmonic generation (HHG) provides a laboratory-scale source of coherent radiation ideally suited to lensless coherent diffractive imaging (CDI) in the EUV and x-ray spectral region. Here we demonstrate transmission extreme ultraviolet (EUV) ptychography, a scanning variant of CDI, using radiation at a wavelength around 29 nm from an HHG source. Image resolution is diffraction-limited at 54 nm and fields of view up to ∼100  μm are demonstrated. These results demonstrate the potential for wide-field, high-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(25 citation statements)
references
References 19 publications
0
25
0
Order By: Relevance
“…However, the use of a beamstop often complicates the experimental design and is very time-consuming. Second approach is to stitch different diffraction patterns recorded for various exposure durations, while removing the oversaturated signal 44 . Care must be considered in reading the sensor output, because artefacts (e.g., saturation trail) might occur for oversaturated CCD sensors.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the use of a beamstop often complicates the experimental design and is very time-consuming. Second approach is to stitch different diffraction patterns recorded for various exposure durations, while removing the oversaturated signal 44 . Care must be considered in reading the sensor output, because artefacts (e.g., saturation trail) might occur for oversaturated CCD sensors.…”
Section: Resultsmentioning
confidence: 99%
“…So far, only a few groups have been able to demonstrate ptychographical imaging with tabletop EUV sources, mostly at around 30 nm 43 46 and 13 nm 47 , 48 . In an attempt to achieve a 100 μm–wide field of view within a single ePIE reconstruction, a polychromatic EUV beam around 29 nm was employed to provide a sufficient photon flux 44 . A breakthrough has been recently made by Gardner et al .…”
Section: Introductionmentioning
confidence: 99%
“…The variable aberration was simulated by the first-order Zernike polynomials resulting in a sinusoidal shift of the diffraction pattern in Fourier space with amplitude of 1 pixel and a period of 100 positions. Similar level of instability can be observed in high-resolution laboratory-based EUV microscopy [27,39] or free electron lasers [40]. The wavefront refinement was performed as it is described in Section 2.3.3.…”
Section: Wavefront Variation Refinementmentioning
confidence: 87%
“…Sufficient coherence of the illumination, short term illumination stability and sufficient sampling of the measured patterns are also crucial requirements of ptychography 32,33 and in spite of ptychography offers method to deal with these effects 26,27,34,35 , if these conditions are not met, reconstruction quality will be degraded for a given dose. In particular partially coherent illumination may seem to be an easy way to increase the flux and thus to reduce the exposure time needed to reach a target resolution 36,37 . However, low coherence, similarly to setup vibrations or insufficient diffraction sampling, leads to loss of speckle visibility.…”
Section: Scanning Precisionmentioning
confidence: 99%