1988
DOI: 10.1016/0167-6105(88)90150-x
|View full text |Cite
|
Sign up to set email alerts
|

Wind loading and fatigue behaviour of fixings and bondings of roof coverings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1990
1990
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…Wind 2021, 1 45 dynamic behavior of single-ply membrane roofing systems using a full-scale specimen. Test methods for evaluating the wind resistance of mechanically attached waterproofing systems have been investigated by many researchers, e.g., Gerhardt and Kramer [5,6], Baskaran and Chen [7], and Baskaran et al [8]. In conventional test methods, including the above-mentioned ones, the specimen is subjected to spatially uniform pressure, which may be static or dynamic.…”
Section: Introductionmentioning
confidence: 99%
“…Wind 2021, 1 45 dynamic behavior of single-ply membrane roofing systems using a full-scale specimen. Test methods for evaluating the wind resistance of mechanically attached waterproofing systems have been investigated by many researchers, e.g., Gerhardt and Kramer [5,6], Baskaran and Chen [7], and Baskaran et al [8]. In conventional test methods, including the above-mentioned ones, the specimen is subjected to spatially uniform pressure, which may be static or dynamic.…”
Section: Introductionmentioning
confidence: 99%
“…For the safe design, it is important to appropriately evaluate the wind-resistant performance of mechanically attached single-ply membrane roofing systems under dynamic wind loading. In Europe, Gerhardt and Kramer [3], [4] developed a test procedure [5] for fatigue evaluation of roof assemblies based on wind climate data. They mentioned that cracks in the steel deck around the boreholes might occur in areas of high external suction while untwisting of the fixation elements might occur when the metal deck was vibrating under relatively small wind loads.…”
Section: Introductionmentioning
confidence: 99%
“…In Europe, the European Technical Construction Agreement (VEAtc) standard wind-uplift test method was prepared based on a procedure developed by Gerhardt and Kramer [6,7]. It is intended for use throughout Europe and provides allowable loads per fastener for mechanically attached systems.…”
Section: Existing Evaluation Proceduresmentioning
confidence: 99%