2012
DOI: 10.1186/1743-0003-9-54
|View full text |Cite
|
Sign up to set email alerts
|

Wireless distributed functional electrical stimulation system

Abstract: BackgroundThe control of movement in humans is hierarchical and distributed and uses feedback. An assistive system could be best integrated into the therapy of a human with a central nervous system lesion if the system is controlled in a similar manner. Here, we present a novel wireless architecture and routing protocol for a distributed functional electrical stimulation system that enables control of movement.MethodsThe new system comprises a set of miniature battery-powered devices with stimulating and sensi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(13 citation statements)
references
References 21 publications
1
12
0
Order By: Relevance
“…Two wearable electronic stimulators (7 × 3 × 2.5 cm 3 ) with a total of eight output channels generated compensated currentcontrolled biphasic pulses [21] . The stimulator allows the user to control the pulse frequency, duration, amplitude and delay on each of the channels.…”
Section: Instrumentationmentioning
confidence: 99%
“…Two wearable electronic stimulators (7 × 3 × 2.5 cm 3 ) with a total of eight output channels generated compensated currentcontrolled biphasic pulses [21] . The stimulator allows the user to control the pulse frequency, duration, amplitude and delay on each of the channels.…”
Section: Instrumentationmentioning
confidence: 99%
“…The scope was defined by the requirement to evaluate feasibility. The literature shows one provisional paper regarding a wireless FES solution [1]. Most commercially available products for FES in sport and rehabilitation are not currently wireless (an exception is the COMPEX Wireless system from Compex) but the technology is promising for a range of products and applications.…”
Section: Introductionmentioning
confidence: 99%
“…The acquisition system used for data collection is a distributed wireless sensor network (Djuric-Jovicic et al, 2011, Jovicic et al, 2012. SU were placed as shown in …”
Section: Procedures For Testing the Methodsmentioning
confidence: 99%
“…The criterion for choosing redirection node is based on the equalization of delays from all nodes -redirection node should be the one that has the shortest delay of its data, as explained in (Jovicic et al, 2012). Central node is connected with computer using USB connection.…”
Section: Other Gait Analysis Technologiesmentioning
confidence: 99%
See 1 more Smart Citation