2020
DOI: 10.1038/s41598-020-77953-8
|View full text |Cite
|
Sign up to set email alerts
|

Wireless, miniaturized, semi-implantable electrocorticography microsystem validated in vivo

Abstract: This paper reports on the design, development, and test of a multi-channel wireless micro-electrocorticography (µECoG) system. The system consists of a semi-implantable, ultra-compact recording unit and an external unit, interfaced through a 2.4 GHz radio frequency data telemetry link with 2 Mbps (partially used) data transfer rate. Encased in a 3D-printed 2.9 cm × 2.9 cm × 2.5 cm cubic package, the semi-implantable recording unit consists of a microelectrode array, a vertically-stacked PCB platform containing… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 33 publications
(43 reference statements)
0
2
0
Order By: Relevance
“…The proposed LS is allowed to work only during the PD; therefore, the integral bounds of ( 6) are from t0 to t0+tpr, where t0 indicates the exact start time of the LS input signal (IN) going up and t0+tpr indicates the moment that VA reaches VM. Thus, replacing VA by VM in (6) and evaluating this integral over the rising PD tpr yields (7) Which can be approximated using Simpson's rule (8) Replacing dt by a time interval ∆t in (3) yields (9) where ∆𝑉 𝐴 is the variation of VA over the time interval ∆t. The value of Cp is determined by (10) In (10), the value of iSDMP2 depends on the region of operation of MP2.…”
Section: Cdmp4=cdsmp4+cdgmp4mentioning
confidence: 99%
“…The proposed LS is allowed to work only during the PD; therefore, the integral bounds of ( 6) are from t0 to t0+tpr, where t0 indicates the exact start time of the LS input signal (IN) going up and t0+tpr indicates the moment that VA reaches VM. Thus, replacing VA by VM in (6) and evaluating this integral over the rising PD tpr yields (7) Which can be approximated using Simpson's rule (8) Replacing dt by a time interval ∆t in (3) yields (9) where ∆𝑉 𝐴 is the variation of VA over the time interval ∆t. The value of Cp is determined by (10) In (10), the value of iSDMP2 depends on the region of operation of MP2.…”
Section: Cdmp4=cdsmp4+cdgmp4mentioning
confidence: 99%
“…Wireless power transfer (WPT) has been widely used in various applications, such as charging portable devices, electric vehicles, renewable energy resources, and implantable medical devices (IMDs), including retinal prostheses, cochlear implants, and neural recording microsystems [1][2][3][4][5][6]. The WPT system can effectively transmit power from the source to the targeted moving device by electromagnetic induction with a lack of radiation.…”
Section: Introductionmentioning
confidence: 99%