2012
DOI: 10.1109/tasc.2012.2182972
|View full text |Cite
|
Sign up to set email alerts
|

Worldwide Benchmarking of ITER Internal Tin ${\rm Nb}_{3}{\rm Sn}$ and NbTi Strands Test Facilities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
30
0

Year Published

2012
2012
2025
2025

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 37 publications
(31 citation statements)
references
References 11 publications
1
30
0
Order By: Relevance
“…To ensure the pressure of the helium remained close to atmospheric pressure, bubblers were used. A temperature correction associated with the liquid helium bath temperature being different to 4.2 K was then applied [1]. For the measurements made below 4.2 K, standard vapour-pressure thermometry was employed.…”
Section: Measurement Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…To ensure the pressure of the helium remained close to atmospheric pressure, bubblers were used. A temperature correction associated with the liquid helium bath temperature being different to 4.2 K was then applied [1]. For the measurements made below 4.2 K, standard vapour-pressure thermometry was employed.…”
Section: Measurement Proceduresmentioning
confidence: 99%
“…In order to standardize critical current density (JC) measurements, ITER has specified a barrel for V-I transport measurements. This approach means one can compare data from different laboratories without explicitly considering self-fields and has led to experimental uncertainty in JC between different institutions to be as low as 2 -3 % [1], [2]. However to optimize our use of superconducting strands, we need to quantify the role of self-field in these measurements given that some work in the literature suggests the self-field corrections can be as large as 6 % [3], [4].…”
Section: Introductionmentioning
confidence: 99%
“…The sample holder with clamping contacts, which allows performing measurements of eight samples at the same time, was used. This measuring system and the measuring method successfully passed the benchmarking organized by the IO ITER [5]. Test facility details were described in our previous work [1].…”
Section: Test Facility To Measure Rrrmentioning
confidence: 99%
“…30 m of un-reacted strand was shipped to ASIPP for the benchmarking. 1 km NbTi strand of the PF strand type S1 with 0.73 mm diameter, produced in Russia, was donated by Chepetsky Mechanical Plant for the benchmarking [4]. A micrograph of the transverse cross-section of the strand is shown in Fig.…”
Section: Samples and Sample Preparationmentioning
confidence: 99%