Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid

Abstract: Rq q-axis rotor voltage. u fed d-axis line side converter reference voltage. u feq q-axis line side converter reference voltage. ω mS Stator frequency. ω S Stator frequency. U S Stator voltage. U ac Grid voltage. U dc DC link voltage. i dc DC link current. i L DC link load current. i Ld d-axis nonlinear load current. i Lq q-axis nonlinear load current. i Ldh d-axis harmonic components of load current. i Lqh q-axis harmonic components of load current. ε Angle between stationary axis and rotor axis. µ Angle betw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
92
0
4

Year Published

2011
2011
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 174 publications
(99 citation statements)
references
References 15 publications
3
92
0
4
Order By: Relevance
“…[2].For the stator side converter, an indirect current control scheme is applied. As the control operation is based on switching, that needs control signals for converter operation.…”
Section: System Descriptionmentioning
confidence: 99%
See 2 more Smart Citations
“…[2].For the stator side converter, an indirect current control scheme is applied. As the control operation is based on switching, that needs control signals for converter operation.…”
Section: System Descriptionmentioning
confidence: 99%
“…In simple terms, a stand-alone generator refers to an isolated grid feeding a local load [2]. In the case of gridconnected variable-speed wind turbines, the total active power can be fed to the grid.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The accurate knowledge of the generator rotor position is required to estimate the suitable value of the current flowing in the rotor terminal. Further, in [15] the rotor position estimation technique is presented for the nonlinear loads. The rotor position or speed estimation techniques are more advantageous in compare to methods based on using the sensors due to less maintenance, reliable and cost effective solution [16]- [20].…”
Section: Introductionmentioning
confidence: 99%
“…The stator of DFIG is directly connected to the grid and the rotor is connected to the grid by a bi-directional converter as shown in Figure 1. The converter connected to the rotor controls the active and the reactive power between the stator of the DFIG and ac supply or a stand-alone grid (Jain & Ranganathan, 2008). The control of the wind turbine systems is traditionally based on either stator-flux-oriented (Chowdhury & Chellapilla, 2006) or stator-voltage-oriented (Hopfensperger et al, 2000) vector control.…”
Section: Introductionmentioning
confidence: 99%