X-ray radiography of AISI 4340-2205 steels welded by friction welding

Abstract: In this study, X-ray radiographic tests of friction-welded AISI 4340-AISI 2205 steels were investigated. AISI 4340 tempered steel and AISI 2205 duplex stainless steel, each of 12 mm diameter, were used to fabricate the joints. The friction-welding tests were carried out using a direct-drive-type friction-welding machine for different parameters. After this process, the radiographic tests of the welded joints were examined by X-ray diffraction. The experimental results indicated that the AISI 4340 tempered stee… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 14 publications
1
3
0
Order By: Relevance
“…This result is identical to FW between SAF 2507 and mild steel obtained by Gardi [21]. Moreover, the amount of flash increased with an increase in friction pressure, the same result obtained for FW between AISI 2205 and AISI 4340 in [16].…”
Section: Visual Examinationssupporting
confidence: 85%
See 1 more Smart Citation
“…This result is identical to FW between SAF 2507 and mild steel obtained by Gardi [21]. Moreover, the amount of flash increased with an increase in friction pressure, the same result obtained for FW between AISI 2205 and AISI 4340 in [16].…”
Section: Visual Examinationssupporting
confidence: 85%
“…Ajith, et al [10][11][12][13] jointed two bars of 2205 DSSs and evaluated the mechanical properties and microstructure, optimized and performed several experiment to evaluate joint characterization, while Mercan, et al [14] optimized the welding parameters that affect increasing the fatigue strength of the joint between AISI 2205 and AISI 1020 bars. Caligulu, et al [15][16][17] welded AISI 4340-2205 steels and studied the impact of rotation speed and friction time, use the X-ray radiographic tests and found the weldability. Kirik, et al [18] connected AISI 2205 to Ti6Al4V with and without nickel interlayer.…”
Section: Introductionmentioning
confidence: 99%
“…S690QL microalloyed steel was joined by using SAW process at 300, 350, 450 A welding current and 46 cm/min constant welding speeds. According to the International Institute of Welding, welding defects and the explanations of the radiographic images were defined as in Table 5 [18][19][20]. The image was assessed according to Table 5.…”
Section: Resultsmentioning
confidence: 99%
“…According to these standards, the investigated area covers the weld and heataffected zone (Figure 2). The X-ray tension chosen according to the thickness of the material was 130 kV (Figure 3) [18][19][20]. The X-ray device, Rigaku Radioflex-300EGS3 type, having the capacity of 300KV was used (Figure 4a-b).…”
Section: Experimental Partmentioning
confidence: 99%