X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders during diagnostic radiographic procedures of the equine vertebral column and limbs

Abstract: OBJECTIVE The objectives of this study were to investigate scattered radiation doses to the hands of equine workers holding the cassette and the x-ray tube by hand, for both limb and vertebral column studies, and to compare the scattered radiation attenuation of lead with radiation protection lead-free gloves. Radiation doses to the hands of the cassette holder in the primary beam were also investigated. SAMPLE A whole-body horse cadaver. PROCEDURES A portable x-ray unit was used to simulate 6 radiographic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…A recent study simulating exposure from scattered radiation in equine radiography to the hands of workers holding the cassette or the x-ray generator found that doses ranged from 0.26 to 2.64 µGy/study −1 and from 0.84 to 12.09 µGy/study −1 , respectively, without the use of hand shielding. Hand shielding reduced doses by at least 98%, depending on the type of glove used (Belotta et al., 2022). (123) In some cases, such as with interventional radiology, it is necessary for staff to perform a variety of tasks within the radiation field for varying times and at different distances from the source.…”
Section: Application Of the System Of Radiological Protection To Vete...mentioning
confidence: 99%
See 1 more Smart Citation
“…A recent study simulating exposure from scattered radiation in equine radiography to the hands of workers holding the cassette or the x-ray generator found that doses ranged from 0.26 to 2.64 µGy/study −1 and from 0.84 to 12.09 µGy/study −1 , respectively, without the use of hand shielding. Hand shielding reduced doses by at least 98%, depending on the type of glove used (Belotta et al., 2022). (123) In some cases, such as with interventional radiology, it is necessary for staff to perform a variety of tasks within the radiation field for varying times and at different distances from the source.…”
Section: Application Of the System Of Radiological Protection To Vete...mentioning
confidence: 99%
“…A recent study simulating exposure from scattered radiation in equine radiography to the hands of workers holding the cassette or the x-ray generator found that doses ranged from 0.26 to 2.64 µGy/study −1 and from 0.84 to 12.09 µGy/study −1 , respectively, without the use of hand shielding. Hand shielding reduced doses by at least 98%, depending on the type of glove used (Belotta et al., 2022).…”
Section: Application Of the System Of Radiological Protection To Vete...mentioning
confidence: 99%
“…As veterinary staff routinely involved in performing portable equine X-rays also face repeated low-dose exposures in their occupation, ensuring robust radiation safety practices are adhered to is of significant importance to reduce the health risks posed by this. A study on the radiation exposure of personnel involved in obtaining portable X-rays of a horse’s limbs [ 3 ] found that doses to the hands were decreased by a mean of 99.58% with the use of lead gloves and 98.9% with the use of lead-free gloves, demonstrating the efficacy of radiation protective equipment.…”
Section: Introductionmentioning
confidence: 99%