XEN®-63 Compared to XEN®-45 Gel Stents to Reduce Intraocular Pressure in Glaucoma
Charlotte Evers,
Daniel Böhringer,
Sara Kallee
et al.
Abstract:The XEN® gel stent reduces intraocular pressure (IOP) in glaucoma. XEN®-45 is widely used; the newer XEN®-63 has a larger lumen targeting potentially lower IOP outcomes. We retrospectively compared the first 15 XEN®-63 cases to 15 matched XEN®-45 controls. With a preoperative IOP of 18.1 ± 3.9 mmHg (mean ± SD) and a final IOP of 9.1 ± 2.0 mmHg, XEN®-63 implantation resulted in an IOP reduction of 44.6 ± 16.5%. Similarly, with a preoperative IOP of 18.3 ± 4.5 mmHg and a final IOP of 10.3 ± 2.1 mmHg, XEN®-45 imp… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.