XEN45 Implant in Medically Controlled vs. Uncontrolled Eyes—Differential IOP Changes in Real-Life Conditions
Gemma Julio,
Raquel Larena,
Marta Mármol
et al.
Abstract:Background: To assess intraocular pressure (IOP) changes and complications after XEN45 implants in medically controlled eyes (MCE) vs. medically uncontrolled eyes (MUE). Methods: A retrospective study, in a tertiary referral hospital, on mild-to-moderate primary open-angle glaucoma (POAG) cases under topical medication, including 32 eyes with IOP < 21 mmHg (MCE group) and 30 eyes with IOP ≥ 21 mmHg (MUE group). The success criteria using Kaplan–Meier analysis was IOP < 21 mmHg without medications (comple… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.