Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
39
0

Year Published

2001
2001
2020
2020

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 97 publications
(44 citation statements)
references
References 16 publications
5
39
0
Order By: Relevance
“…Although the 240 Pu/ 239 Pu atom ratios are not certified, the ratios obtained for the reference samples (Table 4) agree with other reported values using various analytical techniques such as ICP-MS, accelerator mass spectrometry, thermal ionisation mass spectrometry and high-resolution ␣-spectrometry [6,19,[27][28][29]32,[35][36][37][38][39][40][41][42][43][44][45][46]. The precisions (n = 10) of the measurements ranged from 1.7% to 8.6% depending on the total Pu concentrations in the samples.…”
Section: Validation Of Analytical Methodssupporting
confidence: 85%
“…Although the 240 Pu/ 239 Pu atom ratios are not certified, the ratios obtained for the reference samples (Table 4) agree with other reported values using various analytical techniques such as ICP-MS, accelerator mass spectrometry, thermal ionisation mass spectrometry and high-resolution ␣-spectrometry [6,19,[27][28][29]32,[35][36][37][38][39][40][41][42][43][44][45][46]. The precisions (n = 10) of the measurements ranged from 1.7% to 8.6% depending on the total Pu concentrations in the samples.…”
Section: Validation Of Analytical Methodssupporting
confidence: 85%
“…Mass spectrometric techniques such as TIMS [275], AMS [276][277], RIMS [97,278], and ICP-MS [64,[279][280][282][283] have also been used for the determination of Pu isotopes. During the last decade, the use of ICP-MS has gained a increased interest as an alternative to alpha spectrometry because of the good sensitivity, short analytical time and 239 Pu -240 Pu - 242 Pu isotopic information which are difficult to obtain through alpha spectrometry due either to overlapping peaks of 239 Pu at low levels (fg-pg range).…”
Section: Plutonium Isotopesmentioning
confidence: 99%
“…Ion exchange separation using large-size columns is therefore a common technique for isolation of Pu in complex matrices. Due to the pronounced ability of actinides in the higher oxidation states to form anionic complexes, anion exchange chromatography using Dowex 1(or Bio-Rad AG 1 or AG MP-1) resins [49,50,56,59,62,73,79], is the most widely accepted method, whereas the cation exchange process is seldom employed [80] .…”
Section: Ion Exchange Chromatographymentioning
confidence: 99%
“…In a number of radiochemical procedures, UTEVA resin has been employed in combination with TRU resin [62] and other resins. Toribio et al [65], for example, devised an extraction chromatographic method for separation of Pu in soils and sediments by coupling UTEVA and TRU resins in tandem to improve the separation efficiency.…”
Section: Coupling Of Extraction Columnsmentioning
confidence: 99%
See 1 more Smart Citation