2016
DOI: 10.1097/md.0000000000004487
|View full text |Cite
|
Sign up to set email alerts
|

Zero-fluoroscopy catheter ablation of severe drug-resistant arrhythmia guided by Ensite NavX system during pregnancy

Abstract: Background:Cardiac arrhythmias can occur during pregnancy. Owing to radiation exposure and other uncertain risks for the mother and fetus, catheter ablation has rarely been performed and is often delayed until the postpartum period. We reported 2 pregnant women who were experiencing severe arrhythmias and were successfully ablated without fluoroscopic guidance. We also carried out a literature review of cases of pregnant women who underwent zero-fluoroscopy ablation.Methods and Results:One woman had drug-resis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
53
2
5

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 57 publications
(61 citation statements)
references
References 42 publications
1
53
2
5
Order By: Relevance
“…Medical staffs who wear lead garments also reduce exposure to ionizing radiation; however, heavy lead apparel increases workplace discomfort and the risk of neck, back, and joint complications. Some studies have confirmed that interventional cardiologists had experienced an alarming incidence of spinal complaints [16]. Intracardiac echocardiography (ICE) has allowed identification of anatomic structures and potential anatomic variations, and has served to guide catheter navigation, which minimized radiation exposure to operators and patients [17].…”
Section: Discussionmentioning
confidence: 99%
“…Medical staffs who wear lead garments also reduce exposure to ionizing radiation; however, heavy lead apparel increases workplace discomfort and the risk of neck, back, and joint complications. Some studies have confirmed that interventional cardiologists had experienced an alarming incidence of spinal complaints [16]. Intracardiac echocardiography (ICE) has allowed identification of anatomic structures and potential anatomic variations, and has served to guide catheter navigation, which minimized radiation exposure to operators and patients [17].…”
Section: Discussionmentioning
confidence: 99%
“…Procedural times were consistent with previous reports on nonpregnant patients undergoing the same procedure. [58][59][60][61][62][63][64][65][66][67][68] The ablation of ventricular arrhythmias in two pregnant patients, one with idiopathic right ventricular outflow-tract (RVOT) VPC and the other with VT (RVOT anterior) due to electrical storm in ARVC, were also successfully performed with the use of three-dimensional EAM.…”
Section: State Of Fluoroless Procedures For Special Populationsmentioning
confidence: 99%
“…Электрическая кардиоверсия применяется при неэффективности медикаментозной терапии или в экстренных случаях. Имплантируемые кардиовертеры-дефибрилляторы используются у пациенток с высоким риском развития вне зап ной сердечной смерти вследствие необратимых причин [21][22][23].…”
Section: желудочковая тахикардияunclassified