1994
DOI: 10.1016/0009-2614(94)00476-5
|View full text |Cite
|
Sign up to set email alerts
|

Zero-kinetic-energy photoelectron spectroscopy of Ar(2p)-excited argon clusters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
14
1

Year Published

1994
1994
2018
2018

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(17 citation statements)
references
References 42 publications
2
14
1
Order By: Relevance
“…The spectral shape is found to be unchanged, within the given resolution of the CMA, as the average cluster size is increased. This is in agreement with the results of photoelectron and Auger spectroscopy of condensed and clustered argon, where small shifts relative to the atomic value are found for the Ar(2p) ionization energies (17). For solid argon the Auger lines broaden, but do not shift (18).…”
Section: Resultssupporting
confidence: 80%
See 3 more Smart Citations
“…The spectral shape is found to be unchanged, within the given resolution of the CMA, as the average cluster size is increased. This is in agreement with the results of photoelectron and Auger spectroscopy of condensed and clustered argon, where small shifts relative to the atomic value are found for the Ar(2p) ionization energies (17). For solid argon the Auger lines broaden, but do not shift (18).…”
Section: Resultssupporting
confidence: 80%
“…3 5 eV are observed for surface excitons, whereas bulk core excitons are blue-shifted by = l eV, as observed for the solid (20). For large clusters (N=530) the maximum of the lowest exciton state at 244.8 eV shows a shift which is typical for surface excitons, contrary to total electron yield and ZEKE yields recorded under identical expansion conditions where the contribution of bulk excitons dominates (4,17). We point out that total electron yield spectra, as well as ZEKE yield spectra, do not reflect the actual surface-to-bulk ratio of the neutral cluster size distribution since both techniques are particularly sensitive to those electrons which have low kinetic energy.…”
Section: Resultsmentioning
confidence: 47%
See 2 more Smart Citations
“…Cations and electrons are detected alternatively by either a time-of-flight mass spectrometer (cf. [26]) or a threshold photoelectron spectrometer, which relies on angular discrimination of energetic electrons [27]. The experiments are performed in the multi-bunch mode of the storage ring.…”
Section: Methodsmentioning
confidence: 99%