Zinc biosensing with multiphoton excitation using carbonic anhydrase and improved fluorophores

Abstract: Previously, we had shown that the zinc-dependent binding of certain fluorescent aryl sulfonamide inhibitors could be used with apocarbonic anhydrase II to transduce the level of free zinc as a change in the fluorescence of the inhibitor. While inhibitors such as dansylamide, ABD-M, and ABD-N made possible quantitation of free zinc in the picomolar range with high selectivity, they have only modest absorbance which limits their utility. We describe here the synthesis and properties of two new probes, Dapoxyl su… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
4
3

Relationship

4
3

Authors

Journals

citations
Cited by 25 publications
(18 citation statements)
references
References 18 publications
0
18
0
Order By: Relevance
“…Dapoxyl sulfonamide was confirmed by comparison to known samples using thin layer silica chromatography (R f ∼0.8), liquid chromatography-mass spectrometry [LC-MS: m/z (M + H) single peak at 344.0] and fluorescence spectroscopy with an emission peak at 535 nm when excited at 350 nm in the presence of zinc-bound wild type carbonic anhydrase. 24 …”
Section: Synthesis Of Dapoxyl Sulfonamidementioning
confidence: 97%
See 2 more Smart Citations
“…Dapoxyl sulfonamide was confirmed by comparison to known samples using thin layer silica chromatography (R f ∼0.8), liquid chromatography-mass spectrometry [LC-MS: m/z (M + H) single peak at 344.0] and fluorescence spectroscopy with an emission peak at 535 nm when excited at 350 nm in the presence of zinc-bound wild type carbonic anhydrase. 24 …”
Section: Synthesis Of Dapoxyl Sulfonamidementioning
confidence: 97%
“…This procedure also provides time for cells to adjust their zinc concentrations to accommodate the expressed zinc sensors. To verify that the signal increase was specifically caused by DPS binding to holo-CA, ethoxzolamide, a nonfluorescent inhibitor with a much higher affinity for holo-CA affinity (dissociation constant of 1.6 nm compared to 0.1 μM for DPS 24,35 ) was added to the DPS-treated cells. Upon addition of ethoxzolamide, the FRET channel emission decreased and the I FRET /I FP ratio returned to the baseline level (0.19 ± 0.03) [ Fig.…”
Section: Applying Ca_rfp Zinc Sensors In E Colimentioning
confidence: 99%
See 1 more Smart Citation
“…An important potential advantage is that polarization requires no change ofexcitation or emission wavelength, making it particularly well-suited for laser-excited microscopies such as confocal microscopy and multiphoton excitation microscopy. While few reports have appeared describing multiphoton excited fluorescence anisotropy sensing (Thompson, Maliwal, & Zeng, 2000), this technique could potentially be incorporated into an imaging application as well. While filtration to avoid scattered light is important, it is a further advantage that one may use the entire emission band for anisotropy measurements instead of a narrow band for wavelength ratiometric measurements.…”
Section: Advantages Of Anisotropy-based Sensingmentioning
confidence: 99%
“…In particular, Cu 2+ , Co 2+ , Zn 2+ , Cd 2+ , and Ni 2+ have been determined at concentration down the picomolar range (Fierke and Thompson, 2001;Thompson and Jones, 1993;Mey et al, 2011) by changes in fluorescence emission (Thompson et al, 2000) and excitation wavelength ratios (Thompson et al, 2002), lifetimes (Thompson and Patchan, 1995), and anisotropy (polarization) (Elbaum et al, 1996;Thompson et al, 2000). The sensitivity, selectivity, analyte binding, kinetics and stability of the biosensors have been improved by subtle modification of the protein structure by directed mutagenesis (Kiefer et al, 1995;Hunt et al, 1999;DiTusa et al, 2001;McCall et al, 2004;Burton et al, 2000).…”
Section: Carbonic Anhydrase-based Biosensing Of Metal Ionsmentioning
confidence: 99%