Purpose
This non-interventional study investigates variations in the type and frequency of late complications linked to novel zygomatic implant designs, installed adhering to the Zygoma Anatomy-Guided Approach (ZAGA) concept, over an extended follow-up period of at least 3 years.
Methods
Consecutive patients presenting indications for treatment with ZIs were treated according to ZAGA recommendations. Implants were immediately loaded. The ORIS success criteria for prosthetic offset, stability, sinus changes and soft-tissue status were used to evaluate the outcome.
Results
Twenty patients were treated. Ten patients received two ZIs and regular implants; one received three ZIs plus regular implants, and nine received four ZIs. Fifty-nine ZIs were placed: thirty-six (61%) Straumann ZAGA-Flat implants and twenty-three (39%) Straumann ZAGA-Round implants. Four patients (20%) presented earlier sinus floor discontinuities. Fifteen patients (75%) had prior sinus opacities. Nineteen patients were followed for between 38 and 53 months (mean 46.5 months). One patient dropped out after 20 months. When comparing pre-surgical CBCT with post-surgical CBCT, 84.7% of the sites presented identical or less sinus opacity; nine locations (15%) showed decreased, and another nine increased (15%) post-surgical sinus opacity. Fifty-three ZIs (89.8%) maintained stable soft tissue. Six ZIs had recessions with no signs of infection. ZIs and prosthesis survival rate was 100%.
Conclusions
The study highlights the effectiveness of ZAGA-based zygomatic implant rehabilitations using Round and Flat designs. Despite patient number constraints, minimal changes in the frequency of late complications from the 1-year follow-up were observed. 100% implant and prosthesis survival rate over a mean follow-up of 46.5 months is reported.
Graphical Abstract