γ-Fe2O3/CNTs Composites for Electrochemical Detection of Paracetamol: Synthesis, Phase Transition and Enhanced Properties

Abstract: In this work, γ-Fe2O3/CNTs composite was facile synthesized by simple hydrothermal method and hydrazine hydrate treatment at low temperature (CNTs = carbon nanotubes). The result of VSM shows that the saturation magnetization of Fe2O3/CNTs composites increase from 0 to 1.29 emu g−1 after hydrazine hydrate treatment, indicating that the Fe2O3 in the composite transforms from α phase to γ phase. Moreover, the electrochemical properties of both α-Fe2O3/CNTs and γ-Fe2O3/CNTs was studied. Compared with α-Fe2O3/CNTs… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 56 publications
0
5
0
Order By: Relevance
“… Analyte Electrode LDR / μM LOD / nM Ref. FVP CPT-BDD/GCE 0.064 – 130 18.0 [10] MnO 2 -rGO SPE 0.01 – 55 9.0 [11] DNPs/CPE 0.02 – 1.0 4.83 [12] GC/MWCNTs + ILCs 0.9 – 150 16.0 [13] Pt@rGO/GCE 3.16 – 100 2460 [14] PCT AuNPs/ MWCNT/GCE 0.09 – 35 30 [39] PEDOT/GO/GCE 10 – 60 570 [40] Pt/NDG 0.05 – 90 8.0 [41] GCE/Pd-SB 1.0 – 50 67 [42] γ-Fe 2 O 3 /CNTs 2.5 − 385 46 [43] ZnO/FMWCNT/CPE 0.5 – 13 23 [44] FVP Au@CCB/GNFPE 0.03 – 77.3 8.1 This work FVP and PCT Au@CCB/GNFPE FVP: 0.03 – 75PCT: 0.05 – 50 7.54.3 Note: LOD (limit of detection) LDR (linear dynamic range), GCE (glassy carbon electrode), PEDOT (poly(3, 4-ethylenedioxythiophene), GO (graphene oxide), Pt (platinum), NDG (nitrogen doped graphene), Pd-SB (Pd-Schiff base), CPT-BDD GCE (cathodically pretreated boron-doped diamond glassy carbon electrodes), MnO 2 -rGO SPE (MnO 2 -reduced graphene oxide screen-printing electrodes), DNPs/CPE (diamond nanoparticles/carbon paste electrode), GC/MWCNTs+ILCs (glassy carbon / carbon nanotubes-ioni...…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“… Analyte Electrode LDR / μM LOD / nM Ref. FVP CPT-BDD/GCE 0.064 – 130 18.0 [10] MnO 2 -rGO SPE 0.01 – 55 9.0 [11] DNPs/CPE 0.02 – 1.0 4.83 [12] GC/MWCNTs + ILCs 0.9 – 150 16.0 [13] Pt@rGO/GCE 3.16 – 100 2460 [14] PCT AuNPs/ MWCNT/GCE 0.09 – 35 30 [39] PEDOT/GO/GCE 10 – 60 570 [40] Pt/NDG 0.05 – 90 8.0 [41] GCE/Pd-SB 1.0 – 50 67 [42] γ-Fe 2 O 3 /CNTs 2.5 − 385 46 [43] ZnO/FMWCNT/CPE 0.5 – 13 23 [44] FVP Au@CCB/GNFPE 0.03 – 77.3 8.1 This work FVP and PCT Au@CCB/GNFPE FVP: 0.03 – 75PCT: 0.05 – 50 7.54.3 Note: LOD (limit of detection) LDR (linear dynamic range), GCE (glassy carbon electrode), PEDOT (poly(3, 4-ethylenedioxythiophene), GO (graphene oxide), Pt (platinum), NDG (nitrogen doped graphene), Pd-SB (Pd-Schiff base), CPT-BDD GCE (cathodically pretreated boron-doped diamond glassy carbon electrodes), MnO 2 -rGO SPE (MnO 2 -reduced graphene oxide screen-printing electrodes), DNPs/CPE (diamond nanoparticles/carbon paste electrode), GC/MWCNTs+ILCs (glassy carbon / carbon nanotubes-ioni...…”
Section: Resultsmentioning
confidence: 99%
“…The sensitivity of the sensing electrode toward the determination of PCT and FVP was observed to be 11.8 and 6.8 μ A μ M -1 cm -2 , respectively. The performance of the Au@CCB/GNFPE sensor in comparison with other published platforms for the detection of PCT [39] , [40] , [41] , [42] , [43] , [44] and FVP is shown in Table 3 . The proposed sensor exhibited a broad linear range and lower detection limits for both the antiviral drug FVP and the co-administered drug PCT when compared with previously reported values.…”
Section: Resultsmentioning
confidence: 99%
“…Many methods are described in the literature that can measure MPV or PCM using HPLC, [12][13][14] UV spectrophotometry, 15,16 and electrochemical methods. [17][18][19][20][21][22][23][24][25][26][27][28] However, except for electrochemical methods, all other analytical methods are complicated, tedious, timeconsuming, and expensive. Electrochemical methods are timesaving, simple, real-time, user-friendly, and economically worthwhile.…”
Section: Introductionmentioning
confidence: 99%
“…In the literature, there are examples of the use of the α-Fe 2 O 3 and CNT composites in the modification of electrodes. They have been primarily used for the electroanalytical determination of drugs [41][42][43].…”
Section: Introductionmentioning
confidence: 99%