2018
DOI: 10.1016/j.aca.2018.07.018
|View full text |Cite
|
Sign up to set email alerts
|

ε-MnO2-modified graphite electrode as a novel electrochemical sensor for the ultrasensitive detection of the newly FDA approved Hepatitis C antiviral drug ledipasvir

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
14
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 31 publications
(15 citation statements)
references
References 20 publications
1
14
0
Order By: Relevance
“…The obtained results showed that the formed flakes of X.O. facilitates the charge transfer between the modified electrode surface and oxidized/reduced forms of K 3 [Fe(CN) 6 ] due to the increase in the oxidation/reduction kinetics and larger electroactive surface area of X.O./PGE if compared to bare PGE .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The obtained results showed that the formed flakes of X.O. facilitates the charge transfer between the modified electrode surface and oxidized/reduced forms of K 3 [Fe(CN) 6 ] due to the increase in the oxidation/reduction kinetics and larger electroactive surface area of X.O./PGE if compared to bare PGE .…”
Section: Resultsmentioning
confidence: 99%
“…It involves first the removal of one electron from the nitrogen atom of the amidic linkage with the formation of a radical cation . Then in the presence of a water molecule, cleavage of the amidic bond occurs, which involves the loss of methyl carbamate moiety as shown in Scheme . In the presented oxidation scheme the oxidation and cleavage occurs only at one amidic group due to structure bulkiness and the orientation of molecule with respect to the surface of the electrode.…”
Section: Resultsmentioning
confidence: 99%
“…In order to ensure a reproducible electroactive surface area, the same length of the pencil lead is always left outside the support and introduced in the voltametric solution. Electrical contact with the instrument is realized by means of a conductive wire which was soldered or wrapped to the metallic part of the mechanical pencil holder [9,19,21,22,[24][25][26][27][28][29][30][31][32][33][34][35][36][37] (Figure 1a). A micropipette tip [38], an insuline syringe [39], a glass cappilary [40,41], or a plastic [16,[42][43][44][45][46] (Figure 1b) or Teflon tube [47][48][49][50][51][52] (Figure 1c,d) can also act as holder.…”
Section: Pge Manufacturing Proceduresmentioning
confidence: 99%
“…Drop coating was applied to produce Mo 5 O 8 /PGE [34], Trypan blue-modified PGEs [44], different CNT-modified PGEs [47,57,58,68], or PGEs covered with various modifiers [41,49,62,65,135]. After that, the modified PGE was dried either in air [35,48,52,66,68,69,90,136] or in other well-established conditions (e.g., in a desiccator [50] or at a certain temperature [125,137]). The substrate could be either inactivated or electrochemically treated (ET) PGEs (Table 3).…”
Section: Applications Of (Electro)chemically Modified Pges To the Vol...mentioning
confidence: 99%
“…36,37 Activated charcoal (ACH) possess also matchless properties with respect to its nontoxic nature, low cost, commercial-availability from extensive natural sources, broad distribution in pore size, electrical conductivity compared with other competitive adsorbents (e.g., CNTs, zeolite and even graphene). 9,[38][39][40][41][42][43][44] These properties make ACH more benefit adsorbing and electro-sensing agent for wide using in various applications. 45 Here, we first demonstrated the in situ preparation of reduced graphene oxide based silver nanoparticles-containing composite (Ag@rGO) with the aid of an in situ reduction way.…”
mentioning
confidence: 99%