Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Objective Based on the physical principle of the heterodyne laser Doppler vibration measurement process, we analyze the measurement process of highfrequency and lowspeed movement in the presence of lowfrequency and highspeed background movement. In the process, the measurement noise generated by the presence of stray light exhibits chirp characteristics, with the effects and patterns of chirp noise explained. In response to the chirp noise, we propose a derivative preprocessing method for demodulation. The theoretical analysis shows the method exerts a significant effect on suppressing chirp noise, which is verified by simulations and experiments. Meanwhile, we set a heterodyne laser Doppler vibration measurement system with stray light and measure the target vibration. The normal method and derivative preprocessing method are adopted respectively for demodulation. The experimental results verify the existence of chirp noise and the effectiveness of the derivative preprocessing method in suppressing chirp noise, which decreases the chirp noise power by about 81.8%. The method can effectively reduce the influence of stray light on vibration measurement.Heterodyne laser Doppler vibration measurement technology is a widely adopted noncontact and nondestructive movement measurement method, with the advantages of fast response speed and high resolution. It has a strong detection ability for single frequency movement and can quickly identify the characteristic frequency of target movement. However,
Objective Based on the physical principle of the heterodyne laser Doppler vibration measurement process, we analyze the measurement process of highfrequency and lowspeed movement in the presence of lowfrequency and highspeed background movement. In the process, the measurement noise generated by the presence of stray light exhibits chirp characteristics, with the effects and patterns of chirp noise explained. In response to the chirp noise, we propose a derivative preprocessing method for demodulation. The theoretical analysis shows the method exerts a significant effect on suppressing chirp noise, which is verified by simulations and experiments. Meanwhile, we set a heterodyne laser Doppler vibration measurement system with stray light and measure the target vibration. The normal method and derivative preprocessing method are adopted respectively for demodulation. The experimental results verify the existence of chirp noise and the effectiveness of the derivative preprocessing method in suppressing chirp noise, which decreases the chirp noise power by about 81.8%. The method can effectively reduce the influence of stray light on vibration measurement.Heterodyne laser Doppler vibration measurement technology is a widely adopted noncontact and nondestructive movement measurement method, with the advantages of fast response speed and high resolution. It has a strong detection ability for single frequency movement and can quickly identify the characteristic frequency of target movement. However,
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.