Hot deformation tests were carried out on Al5083 – 2 %(vol) TiC nanocomposite in a temperature range of 250 – 450°C at varying strain rate of 0.01 – 1.0 sec-1. Constitutive models were developed for the prediction of peak flow stress relating strain rate, true stress, temperature and activation energy. The percentage error between measured flow stress and constitutive model values were calculated to analyse the efficacy of the model in the prediction of peak stress. Finally, a window of working of the selected nanocomposite is established for finding out the safer region of working.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.