Measurement of bronchial airway responsiveness requires noninvasive techniques in young children. The study was designed to examine the changes in resistance as measured using the interrupter technique (Rint) at the dose of methacholine (M) that induced a fall in transcutaneous partial pressure in O2 (P(tc)O2) > or = 20% (PD(20)P(tc)O2) in young children. Rint was calculated using the linear back-extrapolation method (Rint(L)) and the end-interrupter method (Rint(EI)). Twenty-two children (mean age, 5.2 +/- 1.1 years; range, 3.4 - 7.1 years) with nonspecific respiratory symptoms (mainly chronic cough, n = 17) were tested. P(tc)O2, Rint(L), and Rint(EI) were measured before the test, after saline challenge (baseline (B)), after each dose of M delivered by a dosimeter, and after bronchodilator (BD) inhalation. P(tc)O2 decreased significantly during M challenge, from 85 +/- 6 mmHg (B) to 62 +/- 9 mmHg (P < 0.05), and increased after BD inhalation, to 82 +/- 8 mmHg. Rint(L) and Rint(EI) increased significantly during M challenge, from 0.94 +/- 0.2 KPa/L/s and 1.11 +/- 0.19 KPa/L/s (B) to 1.27 +/- 0.35 KPa/L/s and 1.47 +/- 0.37 KPa/L/s, respectively (P < 0.05), and decreased after BD inhalation to 0.80 +/- 0.17 KPa/L/s and 0.95 +/- 0.18 KPa/L/s, respectively. Nineteen of 22 children reached the PD(20)P(tc)O2 at a dose of M ranging from 50-400 microg. At the PD(20)P(tc)O2, significant changes in Rint(L) and Rint(EI) (sensitivity index (SI) > or = 2) were found in 79% and 63% of children, respectively. We conclude that: 1) M challenge using P(tc)O2 is safe in young children; and 2) our findings are not in favor of the use of Rint as the only indicator of bronchial reaction in young children during M challenge.
In the present study, Rint short-term repeatability was similar to that of previous studies. Similar Rint repeatability in coughers and in asthmatic children favored the use of asthmatic CR for both populations, and a -35% cut-off as a positive BDR. In 20% of study children, baseline Rint variability could influence the significance of the BDR. In order to improve assessment of BDR using Rint, further studies are needed (1) to compare the variability of Rint to other resistance measurement techniques and (2) to define the best method for Rint calculation and for expression of BDR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.