The aim of this study was to develop a specific simulation program for the validation of a cytotoxic compounding robot, KIRO® Oncology, for the preparation of sterile monoclonal antibodies and anti-infectious drugs. The impact of excipient formulations was clearly measured using simulation accuracy tests with worst case excipient (i.e. viscous, foaming) and allowed to correct the robotic settings prior to real production. Corrections brought accuracies within the acceptable range of ±5%. KIRO® Oncology robot has also the capacity of self-cleaning and a simulation combining media fill test, and environmental monitoring was able to validate the aseptic process including simulation of worst case conditions and highlighting the areas not accessible to self-cleaning to be corrected by additional manual cleaning measures. The risk of chemical contamination was simulated by using fluorescent dye of the process with high-risk excipient formulation and overpressure vials. Quality control reliability was simulated by using a model drug, and final concentration was determined by high-performance liquid chromatography-ultraviolet detection. Finally, productivity was simulated using different models of production showing the impact of the type of drug, the number of vials and the poor standardization of the process.
Aims: Azacitidine (AZA), a pyrimidine analogue, is validated for high-risk myelodysplastic syndrome or low-blast acute myeloid leukaemia in unfit patients for more intensive treatment. This study assessed the putative link between cardiac failure (CF) and AZA exposure.Methods: Cases of CF in patients treated with AZA were retrospectively collected and described from several centres of the Groupe Francophone des Myélodysplasies. A description analysis and a disproportionality analysis using Vigibase, the WHO Global Individual Case Safety Reports (ICSRs) database, were conducted on ICSRs by the Standardized MedDRA Queries (SMQ broad) cardiac failure and by preferred terms cardiac failure and cardiac failure acute. The reported odds ratio (ROR) and its 95% 2-sided confidence interval was computed by comparing the proportion of CF reports with the suspected drug (AZA) and the proportion of reports of the same adverse drug reaction with all other suspected drugs in the database during the same period. Results:In the 4 case reports, all patients presented a cardiovascular history. In 1 patient, CF recurred after AZA re-challenge. The pharmacovigilance analysis in Vigibase retrieved 307 ICSRs of CF (SMQ) with AZA. Significant disproportionality signals associated with AZA were identified by using the SMQ cardiac failure (ROR 1.3) and the preferred terms cardiac failure (ROR 5.1) and cardiac failure acute (ROR 23.2). Conclusion:This study points to the potential role of AZA in the occurrence of CF. Cardiac evaluation before AZA initiation and regular monitoring of cardiac function during AZA treatment should be performed in patients with a history of cardiovascular disease. K E Y W O R D Santicancer drugs, drug safety, heart failure
In the context of batch production of cytotoxic drugs in hospital pharmacies with the need of sterility testing, the objective was to validate the use of Rapid Microbiological Method (RMM), and to develop adequate neutralization method in case of inhibition of bacterial growth. The potential microbiological growth inhibitory effect of three anticancer drugs (5 fluorouracil, irinotecan and oxaliplatin) selected for batch production was assessed on BacT/ALERT® system. Among cytotoxic drugs, only 5FU exhibited inhibitory effect on microbiological growth using rapid microbiological method. To counteract this effect our purpose was to use neutralizing agents complexing the drug i. e. activated carbon or ion exchange resins. The microbiological bactericidal concentration of 5FU was very low (1.10–4 mg/mL) indicating the absolute need to neutralize the whole drug before sterility test. The complexation was validated by High Performance Liquid Chromatography control of the residual 5FU concentration in solution after the use of neutralizing agents. Only activated carbon was able to fully capture 5FU when previously diluted at 5 mg/mL. Conversely, the resins, in the condition of the study, were not able to fully capture 5FU whatever the dilution. The microbiological growth on BacT/ALERT® system after active carbon treatment was successfully confirmed with Staphylococcus aureus. Based on this validation results a method was then developed to routinely be able to perform sterility test of the batches produced and was confirmed on five microbiological species (i. e. S. aureus, Pseudomonas aeruginosa, Bacillus subtilis, Candida albicans, Aspergillus brasiliensis). Our work gives a new insight for considering sterility testing by rapid microbiological method even for drugs exhibiting inhibitory effect on microbiological growth.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.