Purpose
The purpose of the research was to develop a method for the determination of temperature characteristics of thermal diffusivity and specific heat on a single and the same stand, powered from an inverter for induction heating. Determination of the thermal diffusivity has been based on the idea of the pulse method. Searched solutions allowed to reduce inaccuracy of the pulse method when such an unusual source of pulse of energy is used.
Design/methodology/approach
Coupled electromagnetic and thermal calculations were carried out to verify proposed methods for estimating thermal properties of an induction heated charge. Presented methods were applied into a real laboratory stand and they were examined experimentally.
Findings
Achieved results of calculations allow to estimate thermal properties of the induction heated charge with 2 and 5 per cent of uncertainty, respectively, for heat capacity and thermal diffusivity. It gives possibility to use results as an input for further proceedings connected with estimation of electrical parameters in a more complex system.
Practical implications
Presented methods of estimating thermal properties of the induction heated charge were verified experimentally on a dedicated laboratory stand. It gives a practical possibility to implement previously established assumptions and examine them. This is a significant step toward the construction of an easy-to-use device for a comprehensive determination of material parameters of metals directly in the heat treatment plant.
Originality/value
This study presents a trial of implementation of induction heating as a source of energy in the impulse method for estimation of thermal properties of the material. Additionally, it presents a process of improving results achieved with the flash methods which were presented in previous papers. The method of estimation of specific heat which uses induction heating as the heat source was presented too.
Study is presenting the description of the laboratory stand for estimating thermal properties of inductively heated charge and aspects associated with implementing arrangements and control procedures, measuring and data handlings. Results of conducted examinations and practical conclusions resulting from analysis of problems that come across in the performance of a task were made. Streszczenie. Opracowanie przedstawia opis stanowiska laboratoryjnego do szacowania cieplnych parametrów materiałowych indukcyjnie nagrzewanego wsadu oraz aspekty związane z wdrożeniem układów i procedur sterujących, pomiarowych oraz obróbki danych. Przedstawiono rezultaty przeprowadzonych badań oraz wnioski praktyczne wynikające z analizy trudności napotkanych w realizacji zadania. (Wykorzystujące nagrzewanie indukcyjne stanowisko do szacowania cieplnych parametrów materiałowych)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.