To assess the influence of breed, breeding lines, and training on heart size, the vertebral heart size (VHS) was evaluated on left-to-right lateral, right-to-left lateral, dorsoventral, and ventrodorsal thoracic radiographs from 44 whippets free from cardiac and pulmonary disease. In lateral views, the VHS was 11.0 +/- 0.5 vertebrae (mean +/- SD) on right-to-left lateral and 11.3 +/- 0.5 vertebrae on left-to-right lateral radiographs, being larger than the 9.7 +/- 0.5 vertebrae proposed by Buchanan (P<0.0001). The VHS on left-to-right lateral views was larger than on right-to-left lateral views (P<0.0001). The VHS was 10.5 +/- 0.6 vertebrae on dorsoventral radiographs and 11.1 +/- 0.6 vertebrae on ventrodorsal radiographs. Both values were larger than the 10.2 +/- 1.5 vertebrae (dorsoventral) (P<0.0082) or 10.2 +/- 0.8 vertebrae (ventrodorsal) (P<0.0001) proposed by Buchanan. In addition, the VHS on ventrodorsal views was larger than on dorsoventral views (P<0.0001). Dogs out of racing pedigree lines had a significantly larger VHS than those out of show pedigree lines, and trained dogs had a significantly larger VHS than nontrained dogs. Because most trained dogs came out of racing pedigree lines, and all nontrained dogs came out of show pedigree lines, however, it is difficult to determine whether the higher VHS for trained dogs is due to genetic influences or training, or both. In conclusion, it is important to take into account the breed and the radiographic view when evaluating heart size in thoracic radiographs of whippets to avoid overinterpretation of cardiac enlargement in these dogs.
The aim of the study was to establish reference echocardiographic values for whippets, to compare these values with previously published reference values for the general dog population, and to determine whether there is an influence of gender and breeding lines on echocardiographic measurements. Echocardiographic parameters from 105 apparently healthy whippets without cardiac symptoms were used to establish reference values for the breed and to compare these values with two previously reported reference ranges. The coefficients of the allometric equation Y= aM(b), useful to reconstruct normal M-mode and two-dimensional average values for whippets of varying weights, were calculated, as well as the lower and upper limits of the 95% prediction interval. First, we found that whippets have a significantly larger left ventricular diameter, increased left ventricular wall, and interventricular septum thickness than expected, in diastole as well as in systole. Fractional shortening was significantly lower than the reference value. Second, comparing males and females, taking body weight differences into account, females had a significantly larger left ventricular diameter in diastole and systole. Minor differences were found between racing and show pedigree dogs. In conclusion, the results of this study confirm that breed-specific reference values are needed in echocardiography. In whippets, the values found in this study can be used as references in order to avoid overinterpretation of cardiac dilation, hypertrophy, and/or decreased contractility in these dogs.
Obesity and weight loss have been shown to alter thyroid hormone homeostasis in humans. In dogs, obesity is the most common nutritional problem encountered and weight loss is the cornerstone of its treatment. Therefore, it is important to clarify how obesity and weight loss can affect thyroid function test results in that species. The objectives of this study were to compare thyroid function in obese dogs and in lean dogs and to explore the effects of caloric restriction and weight loss on thyroid hormone serum concentrations in obese dogs. In the first experiment, 12 healthy lean beagles and 12 obese beagles were compared. Thyroid function was evaluated by measuring serum concentrations of total thyroxine (TT4), free thyroxine (FT4), total triiodothyronine (TT3), thyrotropin (TSH), and reverse triiodothyronine (rT3) as well as a TSH stimulation test using 75 microg i.v. of recombinant human TSH. In the second experiment, eight obese beagles were fed an energy-restricted diet [average 63% maintenance energy requirement (MER)] until optimal weight was obtained. Blood samples for determination of TT4, FT4, TT3, TSH and rT3, were taken at the start and then weekly during weight loss. Only TT3 and TT4 serum concentrations were significantly higher in obese dogs as compared to lean dogs. In the second experiment, weight loss resulted in a significant decrease in TT3 and TSH serum concentrations. Thus obesity and energy restriction significantly alter thyroid homeostasis in dogs, but the observed changes are unlikely to affect interpretation of thyroid function test results in clinics.
The purpose of this study was to investigate the cardiopulmonary influences of sevoflurane in oxygen at two anaesthetic concentrations (1.5 and 2 MAC) during spontaneous and controlled ventilation in dogs. After premedication with fentany-droperidol (5 microg/kg and 0.25 mg/kg intramuscularly) and induction with propofol (6 mg/kg intravenously) six dogs were anaesthetized for 3 h. Three types of ventilation were compared: spontaneous ventilation (SpV), intermittent positive pressure ventilation (IPPV), and positive end expiratory pressure ventilation (PEEP, 5 cm H2O). Heart rate, haemoglobin oxygen saturation, arterial blood pressures, right atrial and pulmonary arterial pressures, pulmonary capillary wedge pressure and cardiac output were measured. End tidal CO2%, inspiratory oxygen fraction, respiration rate and tidal volume were recorded using a multi-gas analyser and a respirometer. Acid-base and blood gas analyses were performed. Cardiac index, stroke volume, stroke index, systemic and pulmonary vascular resistance, left and right ventricular stroke work index were calculated. Increasing the MAC value during sevoflurane anaesthesia with spontaneous ventilation induced a marked cardiopulmonary depression; on the other hand, heart rate increased significantly, but the increases were not clinically relevant. The influences of artificial respiration on cardiopulmonary parameters during 1.5 MAC sevoflurane anaesthesia were minimal. In contrast, PEEP ventilation during 2 MAC concentration had more pronounced negative influences, especially on right cardiac parameters. In conclusion, at 1.5 MAC, a surgical anaesthesia level, sevoflurane can be used safely in healthy dogs during spontaneous and controlled ventilation (IPPV and PEEP of 5 cm H2O).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.