We evaluated the Cand-Tec (Ramco Laboratories Inc., Houston, Tex.) and LA-Candida antigen detection system (Immuno-Mycologics Inc., Norman, Okla.) tests as possible rapid alternatives to blood cultures for the identification of patients with candidemia. Tests were performed on sera from (i) 33 patients with candidemia, (ii) 82 patients with fever and risk factors for invasive candidiasis, and (iii) 13 healthy controls. A total of 21 patients had no evidence of invasive candidiasis, as determined by clinical course, blood culture, and/or autopsy; results for 61 patients were indeterminate regarding the presence of invasive candidiasis, or else the patients had invasive candidiasis with organ involvement. By using a threshold positive Cand-Tec titer of '1:4, the sensitivity in candidemic patients was 49%; the specificity was 43% (patients with true-negative results had neither candidemia nor other evidence of invasive candidiasis). Coexistent disseminated candidiasis in some candidemic patients may have accounted for some positive Cand-Tec tests and possible overestimation of the sensitivity of the test for candidemia. Cand-Tec test results were negative for healthy controls. All test results obtained by the LA-Candida antigen detection system assay were negative. Our findings indicate that neither of these assays reliably identifies patients with candidemia.
Donor RBCs nonreactive in initial tests for D must be tested further for evidence of weak expression of D antigen. Performing this test in test tubes is labor intensive and prone to inconsistencies in readings (relative strength of agglutination) and interpretation (positive versus negative). These inconsistencies can lead to repeat testing, additional documentation, and delay in releasing units. We evaluated use of the Tecan MEGAFlex-ID™ pipettor to perform this test in anti-IgG gel cards. Results with this semi-automated gel test were compared with results obtained with 37 D– and 99 weak D samples, as determined by previous testing with a manual IAT tube test. Hands-on time was determined for both methods and both methods were evaluated for inconsistency, or nonagreement, between the interpretation of the current weak D test and the results on record for any prior donations. There were no discordant results obtained, with the majority of weak D samples giving stronger reactions with the gel test. The semiautomated gel test required less hands-on time, with an average savings of more than 70 seconds per test. There were no inconsistencies with the gel method, whereas manual tube testing was found to have an inconsistency rate of 0.035 percent of total samples tested. Semiautomated IgG gel is now used for all weak D testing, with a labor savings of more than 10 hours per week. Thus far, more than 70,000 donors have been tested, with no inconsistencies reported. Immunohematology 2003;19:7–9.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.