Carpal tunnel syndrome is caused by the compression of the median nerve as it transits the carpal tunnel, with an incidence of about 1% of the population. If surgery is needed, the treatment involves decompression of the median nerve followed sometimes by musculoskeletal outpatient rehabilitation. This paper presents a proof-of-concept pilot clinical trial in which the Rutgers Masters II haptic glove was tested on five subjects, who were two weeks post-hand surgery. Subjects trained for 13 sessions, 30 min per session, three sessions per week, and had no conventional outpatient therapy. Computerized measures of performance showed group effects in hand mechanical energy (1200% for the virtual ball squeezing and DigiKey exercises and 600% for the power putty exercise). Improvement in their hand function was also observed (a 38% reduction in virtual pegboard errors, and 70% fewer virtual hand ball errors). Clinical strength measures showed increases in grip (by up to 150%) and key pinch (up to 46%) strength in three of the subjects, while two subjects had decreased strength following the study. However, all five subjects improved in their tip pinch strength of their affected hand (between 20%-267%). When asked whether they would recommend the virtual reality exercises to others, four subjects very strongly agreed and one strongly agreed that they would.
Abstract-This study explored the equivalence of physical function assessment by physical therapists (PTs) during faceto-face and remote administration of the European Stroke Scale (ESS) and the Functional Reach Test (FRT) to 26 subjects with a history of stroke. Patients were randomized to remote or face-to-face administration groups. Each patient was simultaneously rated by both the face-to-face and remote PTs. The PTs were blinded to each other's results. Equivalence was set at the 95% limits of agreement. When the face-to-face PT directed the patient, the two PTs reported equivalent values in more than 90% of the patients for the FRT and for all ESS components, with the exception of gait (83%) and maintaining leg position (85%). When the remote PT directed the patient, the two PTs reported equivalent values in more than 90% of the patients for the FRT and more than 83% for all ESS components. Televideo assessment of function by PTs is substantially equivalent to a face-to-face encounter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.