Graves’ orbitopathy (GO) is the most common extrathyroidal manifestation of Graves’ disease (GD). Our aim was to assess the efficacy and safety of Tocilizumab (TCZ) in GO refractory to conventional therapy. This was an open-label multicenter study of glucocorticoid-resistant GO treated with TCZ. The main outcomes were the best-corrected visual acuity (BVCA), Clinical Activity Score (CAS) and intraocular pressure (IOP). These outcome variables were assessed at baseline, 1st, 3rd, 6th and 12th month after TCZ therapy onset. The severity of GO was assessed according to the European Group on Graves’ Orbitopathy (EUGOGO). We studied 48 (38 women and 10 men) patients (95 eyes); mean age ± standard deviation 51 ± 11.8 years. Before TCZ and besides oral glucocorticoids, they had received IV methylprednisolone (n = 43), or selenium (n = 11). GO disease was moderate (n =29) or severe (n = 19) and dysthyroid optic neuropathy (DON) (n = 7). TCZ was used in monotherapy (n = 45) or combined (n = 3) at a dose of 8 mg/kg IV every four weeks (n = 43) or 162 mg/s.c. every week (n = 5). TCZ yielded a significant improvement in all of the main outcomes at the 1st month that was maintained at one year. Comparing the baseline with data at 1 year all of the variables improved; BCVA (0.78 ± 0.25 vs. 0.9 ± 0.16; p = 0.0001), CAS (4.64 ± 1.5 vs. 1.05 ± 1.27; p = 0.0001) and intraocular pressure (IOP) (19.05 ± 4.1 vs. 16.73 ± 3.4 mmHg; p = 0.007). After a mean follow-up of 16.1 ± 2.1 months, low disease activity (CAS ≤ 3), was achieved in 88 eyes (92.6%) and TCZ was withdrawn in 29 cases due to low disease activity (n = 25) or inefficacy (n = 4). No serious adverse events were observed. In conclusion, TCZ is a useful and safe therapeutic option in refractory GO treatment.
Purpose. To evaluate the weight of intraocular lenses (IOLs) depending on their material, dioptric power, toricity, focality, and haptic design. Methods. Twenty-eight different IOL models from nine different medical companies (a total of 38 IOLs) and 1 capsular tension ring (CTR) were evaluated. IOLs were weighed using a precision scale, in hydrated conditions, as an approximation to their intraocular status. Results. Hydrophilic IOLs were heavier than hydrophobic lenses (
p
<
0.001
). Regarding toricity, no statistical differences were found comparing toric to non-toric models (
p
=
0.1
). Likewise, no differences were found between multifocal IOLs and monofocal IOLs (
p
=
0.19
). Dioptric power did not affect IOL weight: IOLs of <15DP had similar weights to those of ≥15D and IOLs of ≥24D had similar weights to those of <24 D (
p
=
0.86
and
p
=
0.59
, respectively). Plate-design IOLs were significantly heavier than 1-piece C-loop (
p
<
0.001
), 3-piece C-loop (
p
<
0.001
), and 4-haptic lenses (
p
=
0.001
). Conclusions. Of the characteristics analyzed that might influence IOL weight, lenses with hydrophilic material and plate-haptic design were found to be heavier. Toricity, focality, and dioptric power had no influence on IOL weight.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.