PCs prepared from a pool of four buffy coats can be filtered and subsequently stored for 8 days (starting +/- 24 hours after whole blood collection) without detriment to platelet function, metabolism, or activation.
The effect of filtration on the quality of platelet concentrates (PC) during storage was investigated. Two leukocyte depletion filters (Pall PL50HF and Sepacell PL-10A) were applied to filter PC made from a pool of 4 huffy coats. For each experiment 3 PC were pooled and divided into 3 identical PC to eliminate differences between the PC. Two PC were filtered, and the third PC served as an unfil- tered control. A total of 12 experiments was performed. Before filtration, volumes of the PC were 263 ± 11.7 ml (mean±SD). Platelet and leukocyte counts per PC were 241±25.9 x 10^9 and7.2±1.8 x 10^6, respectively. After filtration leukocyte counts did not exceed 5 x 10^4 in any of the PC. In the PC filtered with the Pall PL50HF the mean platelet loss was approximately 14% and with the Sepacell PL-10A, 17%. During a 9-day storage period the pH, PO(2), PCO(2), bicarbonate, lactate and glucose concentration and LDH release as well as the morphology, examined by the swirling effect and microscopically, were not significantly different in filtered and unfiltered units. Filtration through the 2 investigated leukocyte depletion filters for PC did not adversely affect in vitro viability of the platelets during storage.
The effect of filtration on the quality of platelet concentrates (PC) during storage was investigated. Two leukocyte depletion filters (Pall PL50HF and Sepacell PL-10A) were applied to filter PC made from a pool of 4 buffy coats. For each experiment 3 PC were pooled and divided into 3 identical PC to eliminate differences between the PC. Two PC were filtered, and the third PC served as an unfiltered control. A total of 12 experiments was performed. Before filtration, volumes of the PC were 263 +/- 11.7 ml (mean +/- SD). Platelet and leukocyte counts per PC were 241 +/- 25.9 x 10(9) and 7.2 +/- 1.8 x 10(6), respectively. After filtration leukocyte counts did not exceed 5 x 10(4) in any of the PC. In the PC filtered with the Pall PL50HF the mean platelet loss was approximately 14% and with the Sepacell PL-10A, 17%. During a 9-day storage period the pH, PO2, PCO2, bicarbonate, lactate and glucose concentration and LDH release as well as the morphology, examined by the swirling effect and microscopically, were not significantly different in filtered and unfiltered units. Filtration through the 2 investigated leukocyte depletion filters for PC did not adversely affect in vitro viability of the platelets during storage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.