The development of a novel and portable tabletop pulsed neutron source is presented. It is a battery powered neutron tube based on a miniature plasma focus (PF) device having all metal-sealed components. The tube, fuelled with deuterium gas, generates neutrons because of D–D fusion reactions. The inner diameter and the length of the tube are 3.4 cm and 8 cm, respectively. A single capacitor (200 J, 4.0 µF, 10 nH) of compact size (17 cm × 15 cm × 13 cm, 6.5 kg) is used as the energy driver. A power supply system charges the capacitor to 10 kV in 10 s and also provides a 30 kV trigger pulse to the spark gap. An input of 24 V dc (7.5 A) to the power supply system is provided by two rechargeable batteries (each 12 V, 7.5 A, 20 h). The device has produced neutrons for 150 shots within a period of 120 days in a very reliable manner without purging the deuterium gas between the shots. For the first 50 shots, the average yield is (1.6 ± 0.3) × 106 neutrons/shot in 4π sr with a pulse width of 23.4 ± 3.3 ns. The estimated neutron energy is 2.47 ± 0.22 MeV. The neutron production reduces slowly and reaches the detection threshold value of 3 × 105 neutrons/shot towards the last shots. The device produces neutrons in a similar manner on evacuation and refilling. The height of the mounted PF tube with the capacitor and the spark gap is 35 cm. The complete setup comprising the capacitor with spark gap, the PF tube, the power supply system with two batteries and the control panel weighs only 23 kg.
Development and operation of a portable and compact pulsed neutron source based on sealed-type plasma focus (PF) device are reported. The unit is the smallest sealed-type neutron producing PF device. The effective volume of the PF unit is 33 cm(3) only. A compact size single capacitor (4 μF) is used as the energy driver. A battery based power supply unit is used for charging the capacitor and triggering the spark gap. The PF unit is operated at 10 kV (200 J) and at a deuterium gas filling pressure of 8 mb. The device is operated over a time span of 200 days and the neutron emissions have been observed for 200 shots without changing the gas in between the shots. The maximum yield of this device is 7.8 × 10(4) neutrons/pulse. Beyond 200 shots the yield is below the threshold (1050 neutrons/pulse) of our (3)He detector. The neutron energy is evaluated using time of flight technique and the value is (2.49 ± 0.27) MeV. The measured neutron pulse width is (24 ± 5) ns. Multishot and long duration operations envisage the potentiality of such portable device for repetitive mode of operation.
Development of a palm top plasma focus device generating (5.2 ± 0.8) × 10(4) neutrons∕pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of (3)He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.
The design and performance of a miniaturized magneto-optic probe using a terbium doped paramagnetic glass are described. The compactness and simplicity of the device are achieved by using the polarizer sheets obtained from a commonly available liquid crystal display. Plastic optical fibers are used to transport the light. A pulsed magnetic field up to 48 T has been generated and measured using high-voltage capacitor discharge in single-turn coils. A rise time and magnetic field-dependent anomalous behavior is observed in the terbium glass characteristics at room temperature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.