Effect of specimen orientation, heat treatment and applied potential on the stress corrosion susceptibility of magnesium AZ61 (Mg‐6.3% Al‐0.5% Zn‐0.20% Mn) alloy in an aqueous 3.5% NaCl + 2% K2CrO4 solution at room temperature was investigated. Stress corrosion times to failure were measured at different values of initial stress intensities using single edge (pre) cracked sheet tensile specimens and a modified tensometer. It was observed that while the specimen orientation has a significant effect on the measured values of stress corrosion threshold stress intensity, KIscc, the effect of varying the quench rate during heat treatment was minimal. Polarization measurements both in stressed and unstressed conditions, failed to reveal any significant effect of the applied stress intensity on the anodic polarization behavior of the alloy. However, measurements made under four different potentiostatic conditions showed a considerable increase in stress corrosion times to failure of the alloy. The results, together with fractographic observations of fractured specimen are discussed in terms of the mechanisms of stress corrosion cracking, in magnesium alloys.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.