531.76.66 Various aspects of the design of microprocessor systems for velocity, acceleration, and position measurements are considered. The velocity-measuring method described differs from known methods in that it has minimal errors in the range of velocities from fractions of a rotation to the maximum rotation frequency and requires a microprocessor. The position and acceleration are measured at the same time as is the velocity.One method of increasing the accuracy of modem electric drives of machine tools and industrial robots is by improving the dynamic and static characteristics of transducers in feedback circuits [1, 2]. The velocity of a controlled drive is generally measured by analog transducers, which reduces the control accuracy, especially in the range of low and ultralow values. Moreover, digital drives (to close the main feedback circuit) as well as analog drives (to close the velocity circuit) are used in autonomous follower drives.Coding transducers with magnetic or optical pickup are used to obtain information about the parameters of motion of an object. Essentially, the velocity is measured by two principal methods [2]: counting pulses from a coding transducer in a fixed interval of time and counting pulses from an auxiliary oscillator during coding transducer pulses. In the first case, the measurement is effective in the range of high velocities and in the second, low velocities. The position of the actuators is determined by directly counting pulses from coding transducers and then covering the count into the actual position.Both methods involve the use of equipment and are simple to apply. The quality of the measurements, however, is not always justified. We consider the salient features of the two methods in greater detail and estimate the data acquisition error.The essence of the direct method consists in measuring the number of sensor pulses in a given period of time. The rotational velocity of the sensor disks is calculated aswhere T is the measuring interval, N is the number of sensor pulses counted in the given time, and Z is the number of pulses per rotation. Even though the characteristic of the given method of measurements is linear over all ranges, measurement of slow velocities is a very complicated process. The main reason why the given method has an error of velocity measurement is that the number N is an integer since most often the pulses are counted by standard counters. As a rule, however, a fractional number of pulses fits in the measuring period T. Accordingly, that period must be increased to reduce the errors. For a wide-range sensor, the necessary measuring period is calculated for the minimum velocity since the sensor pulse frequency then is also a minimum.We consider the distribution of the error of velocity measurement by the given method, depending on the velocity and the measuring period (from Fig. 1).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.