Objective:The objective of this study was to determine the efficacy and safety of temporary pacing with an active fixation lead placed through the internal jugular vein and/or subclavian vein. Methods: We analyzed a consecutive series of 25 out of 73 patients that had a pacemaker extraction and were pacing dependent requiring temporary pacing with an active fixation lead until the new pacemaker implant, from 2017 to 2021. Results: After extraction 25 patients age 68 years ± 16 years, required temporary pacing, the media for temporary pacing was 5 days. There was no mortality associated to temporary stimulation. Only one patient (4%) had a complication 4 days after the implant with capture fail due to a microdislogement requiring reintervention. Conclusion: Temporary stimulation through active fixation pacemaker leads that it is safe and effective.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.