In the recording of biomedical signals, a significant noise component is introduced by the electrode. The magnitude of this noise is considerably higher than the equivalent thermal noise from the electrode impedance. As the noise in surface electrodes limits the resolution of biopotential recordings, it is important to understand its origin. It was found that the noise mainly originates in the electrolyte-skin interface and that it is highly dependent on the electrode gel used and the skin properties of the test subject. Depending on skin treatment, magnitudes between 1 and 20 microVrms were measured among subjects. When the metal-electrolyte interface was allowed time to stabilise, electrodes of different metals measured face to face all showed a negligibly small noise magnitude (< 1 microVrms). In pre-gelled electrodes, where the metal-electrolyte interface has stabilised, no difference in noise properties was found between Ag-AgCl electrodes and other metals when measured on the skin. In subjects at rest, the contribution of EMG signals to the total noise level was shown to be negligibly small compared with the noise contribution of the electrolyte-skin interface. The magnitude of the noise of electrodes appeared to be inversely proportional to the square root of the area of the electrode on the skin.
In the first part of the review the various mechanisms that could be the cause of interference in bioelectric recordings are considered. It is demonstrated that the performance of a good amplifier can be seriously degraded in its functioning if the whole measurement situation is not taken into account. Several techniques used to reduce interference, of which guarding and driven right leg circuits are the most important, are analysed. In the second part of the review some examples of the application of the theory in practical situations are presented. The instrumentation amplifier circuit normally used in bioelectric recordings is improved for measurements under difficult circumstances. Another application is a low-cost 64-channel amplifier for multichannel ECG recordings. The third application is a device that can be added to bioelectric measurement systems and will provide a major reduction in interference.
A mathematical model of the regulation process of the heat shock protein hsp70 in the cell is presented. The model describes the damaging effect of elevated temperature on proteins; the interaction of free hsp70 with injured proteins and its chaperone role in nascent protein translation; the relation between the amount of free hsp70 and the formation of the activated trimer form of the heat shock factor protein (HSF); the binding of activated HSF with the heat shock elements on the DNA; the transcription of mRNA of hsp70 and the synthesis of hsp70. The reaction of the model to a temporal rise in temperature shows an initial decline and a subsequent sharp rise to an ultimately increased level of free hsp70 in the cell. The response of the model to both a single and two consecutive heat shocks appears to closely resemble experimental data on hsp70 synthesis. This general agreement demonstrates the structure of the model to be sound and suitable as a basis for further modelling the complex tolerance mechanism of the cell.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.