The kinetics of the ruthenium(III) chloride (Ru(III))-catalysed oxidation of five N-heterocycles (S) viz. imidazole (IzlH), benzimidazole (BzlH), 2-hydroxybenzimidazole (2-HyBzlH), 2-aminobenzimidazole (2-AmBzlH) and 2-phenylbenzimidazole (2-PhBzlH) by sodium-Nchloro-p-toluenesulfonamide (chloramine-T; CAT) in the presence of HCl has been studied at 313 K. The oxidation reaction follows the identical kinetics for all the five N-heterocycles and obeys the rate law, rate, where x, y and z are less than unity. Addition of p-toluenesulfonamide (PTS) retards the reaction rate. Variation of ionic strength of the medium and the addition of halide ions show negligible effect on the rate of the reaction. The rate was found to increase in D 2 O medium and showed positive dielectric effect. The reaction products are identified. The rates are measured at different temperatures for all substrates and the composite activation parameters have been computed from the Arrhenius plots. From enthalpy-entropy relationships and Exner correlations, the calculated isokinetic temperature (β) of 392 K is much higher than the experimental temperature (313 K), indicating that, the rate has been under enthalpy control. Relative reactivity of these substrates are in the order: 2-HyBzlH > 2-AmBzlH > BzlH > IzlH > 2-PhBzlH. This trend may be attributed to resonance and inductive effects. Further, the kinetics of Ru(III)-catalysed oxidation of these N-heterocycles have been compared with uncatalysed reactions (in the absence of Ru(III) catalyst) and found that the catalysed reactions are 16-20 times faster. The catalytic constant (K C ) was also calculated for each substrate at different temperatures. From the plots of log K C versus 1/T, values of activation parameters with respect to the catalyst have been evaluated. H 2 O + Cl has been postulated as the reactive oxidizing species. The reaction mechanism and the derived rate law are consistent with the observed experimental results.
A rapid, reliable and sensitive LC-MS/MS method for the determination of melatonin in milk was developed and validated. Sample was extracted with dichloromethane and cleaned by passing through Chem Elut solid phase extraction cartridge. The solvent was evaporated to dryness, reconstituted with methanol and analysed by LC-MS/MS on Agilent zorbax Eclipse XDB C-18 rapid resolution analytical column. The analytical procedure was found to be accurate, precise and linear. The method accuracy was 92.2 % (range 90.06-94.58) and the mean precision was 1.55 % and the calibration was linear for 1 to 150 pg mL −1 (R 2 >0.99), the lowest limit of quantification (LLOQ) was 1 pg mL −1. 7-D Melatonin (7-DM) was used as an internal standard. This method was proved to be a promising method for the determination of melatonin for market milk and human milk samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.