THA in patients younger than 30 years old presents challenges: the initial technical challenge relates to the initial disease that often causes deformities making reconstruction difficult, while the long-term challenge is wear and subsequent osteolysis and component loosening. Ceramic-on-ceramic prostheses may represent a valuable option to reduce wear. We retrospectively studied 101 patients (132 hips) with ceramic-on-ceramic prostheses implanted from 1977 to 2004. As a result of the long span of time, different implant designs and modes of fixation were used. The average age of the patients was 23.4 ± 5 years (range, 13-30 years), and the main indication for THA was femoral head necrosis. The minimum followup was 1 year (mean, 6.9 years; range, 1-26.5 years). We documented 17 revisions (13%) for aseptic loosening. Twelve were for isolated acetabular loosening, two for isolated femoral loosening, and three for loosening of both components. Survivorship was 82.1% at 10 years and 72.4% at 15 years. Inferior survivorship was observed for THA performed after secondary arthritis related to slipped capital epiphysis or trauma. Limited osteolysis was observed in one hip. The main limiting factor in this series was the fixation of the acetabular component. However, improvements in the design and in the mode of fixation of this component should enhance long-term results.
Osteonecrosis after bone marrow transplantation is usually severe. Most patients develop acute and chronic graft-versus-host disease requiring a high dose of steroids for a long period of time. Generally ineffective nonoperative treatment in the past has resulted in treatment primarily with total hip arthroplasty (THA). We asked whether THA (1) reliably improved functional status, (2) led to more complications, and (3) THA after bone marrow transplantation was as durable as THA for idiopathic ON. We retrospectively reviewed 77 patients (123 hips) with osteonecrosis. The mean age at surgery was 33 years (range, 15.7-56 years). We performed all arthroplasties with an alumina ceramic bearing coupled with an alumina head 32 mm in diameter. The minimum followup was 2 years (mean, 9.2 years; range, 2-26 years). We documented seven revisions: three for late septic loosening, four for late aseptic loosening. Considering loosening of any component as the end point, the survivorship was 74.8% (range, 58.7%-90.9%) at 10 years. In this difficult situation, we believe the results acceptable. Septic loosening affecting this specific population has to be considered a serious event.
We describe a lateral approach to the distal humerus based on initial location of the superficial branches of the radial nerve, the inferior lateral cutaneous nerve of the arm and the posterior cutaneous nerve of the forearm. In 18 upper limbs the superficial branches of the radial nerve were located in the subcutaneous tissue between the triceps and brachioradialis muscles and dissected proximally to their origin from the radial nerve, exposing the shaft of the humerus. The inferior lateral cutaneous nerve of the arm arose from the radial nerve at the lower part of the spiral groove, at a mean of 14.2 cm proximal to the lateral epicondyle. The posterior cutaneous nerve of the forearm arose from the inferior lateral cutaneous nerve at a mean of 6.9 cm (6.0 to 8.1) proximal to the lateral epicondyle and descended vertically along the dorsal aspect of the forearm. The size and constant site of emergence between the triceps and brachioradialis muscles constitute a readily identifiable landmark to explore the radial nerve and expose the humeral shaft.
S U M M A R Y Considerable research has been focused on the use of bone marrow-derived mesenchymal stem cells (MSCs) for the repair of non-unions and bone defects. To date, the question of whether transplanted MSCs survive and engraft within newly formed tissue remains unresolved. The development of an easy and reliable method that would allow cell fate monitoring in transplant recipients is a pressing concern for the field of tissue engineering. To demonstrate the presence of transplanted cells in newly formed bone, we established a xenograft nude rat model allowing the detection of murine LacZ MSCs in vivo. MSCs were isolated from transgenic lacZ mice, seeded onto bioabsorbable collagen sponges, and transplanted to repair a calvarial defect in nude rats. As a preliminary step, the histological procedure was adapted to optimize the detection of LacZ cells in bone tissue embedded in methylmethacrylate (MMA). Four fixatives and four fixation times were evaluated. Among all the fixatives tested, 2% formaldehyde/0.2% glutaraldehyde at 4C for 4 days gave the best results for X-gal staining at pH 7.4 on both cell cultures and bone explants. All fixatives were effective for imunodetection of b-gal. In the chimeric LacZ/nude rat animal model, MSCs were detected in vivo for up to 4 weeks after implantation and contributed to the repair and the neovascularization of the bone defect. LacZ is a suitable phenotypic marker to track MSCs in skeletal tissues embedded in MMA. (J Histochem Cytochem 55:255-262, 2007)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.