Background. To assess the ability of mid-trimester sFlt-1/PlGF ratio for prediction of preeclampsia in two different Arabic populations. Methods. This study measured levels of sFlt-1, PlGF, and sFlt-1/PlGF ratio at midtrimester in 83 patients who developed preeclampsia with contemporary 250 matched controls. Results. Women subsequently developed preeclampsia had significantly lower PlGF levels and higher sFlt-1 and sFlt-1/PlGF ratio levels than women with normal pregnancies (P < 0.0001 for all). Women who with preterm preeclampsia had significantly higher sFlt-1 and sFlt-1/PlGF ratio than term preeclamptic women (P = 0.01, 0.003, resp.). A cutoff value of 3198 pg/mL for sFlt-1 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 88%, 83.6%, and 84.7%, respectively, with odds ratio (OR) 37.2 [95% confidence interval (CI) 17.7–78.1]. PIGF at cutoff value of 138 pg/mL was able to predict preeclampsia with sensitivity, specificity, and accuracy of 85.5%, 77.2%, and 79.3%, respectively, with OR 20 [95% CI, 10.2–39.5]. The sFlt-1/PIGF ratio at cutoff value of 24.5 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 91.6%, 86.4%, and 87.7%, respectively with OR 67 [95% CI, 29.3–162.1]. Conclusion. Midtrimester sFlt-1/PlGF ratio displayed the highest sensitivity, specificity, accuracy, and OR for prediction of preeclampsia, demonstrating that it may stipulate more effective prediction of preeclampsia development than individual factor assay.