The flow cytometric detection of aberrant antigen expression is one method proposed for the quantification of minimal residual disease (MRD) in acute leukemias. The present study was designed to investigate the stability of the aberrant antigen expression at relapse or at treatment failure of initial chemotherapy. For this purpose, multiparameter immunophenotyping with a panel of 15 monoclonal antibodies was used at diagnosis as well as at relapse (43 patients with overall 65 aberrations) and at treatment failure (35 patients with overall 66 aberrations). There was a significant decrease in the percentage of the initially described aberrant antigen expression on leukemia blasts at relapse (P = 0.001; n = 65) as well as at treatment failure (P = 0.0001; n = 66) considering all aberrations in the whole leukemia population. Concerning only patients with acute myelogenous leukemia (AML), significant decreases in the aberrant expression could be detected at relapse (P = 0.031; n = 42) and at treatment failure (P = 0.0001; n = 52). The changes in patients with acute lymphoblastic leukemia (ALL) were significant only at relapse (P = 0.006; n = 23). Initially, the most informative aberration was not detectable in four patients at relapse and in seven patients at treatment failure. A decrease of under 50% of the initial value was observed in another 8 patients at relapse and in 10 patients at treatment failure. In further studies assessing the detection of aberrant antigen expression for MRD, quantification of the relapses should be explicitly analyzed regarding the persistence of the initially described aberrant antigen expression. Cytometry (Comm. Clin. Cytometry) 42:247–253, 2000. © 2000 Wiley‐Liss, Inc.
The performance of the SE-9000 automated haematology analyser in a laboratory receiving a high number of abnormal specimens from haematological oncology patients was assessed according to formal protocols for the evaluation of blood cell counters. Linearity over a useful working range, precision in clinically important ranges and negligible carry-over were demonstrated in this group of patient samples confirming the results of previous investigators. The comparability of instrument derived differential leucocyte counts from both normal and distributionally abnormal samples with those obtained by visual microscopy using the NCCLS H-20 A protocol was very good. The sensitivity of flags for the detection of immature granulocytes and myeloid blast cells was high and this can be attributed to the incorporation of a new measuring channel (Immature Myeloid Information or IMI channel). The number of unrecognized abnormalities was low and when compared with the poor sensitivity of the routine 100-cell visual differential leucocyte count, the analyser was judged suitable for monitoring patients with haematological malignancies. The performance of flags such as 'left shift' and 'atypical lymphocytes' can be improved by taking into consideration distributional abnormalities such as neutrophilia and lymphocytosis. The trigger level for these flags should be adapted to the clinical need particularly in cases of neutropenia following chemotherapy, and in lymphoproliferative disorders and infection.
No abstract
Transvaginal sonography is an established method for numerous clinical indications in the assessment of endometrium pathology. The investigation of the endometrium consists of the measurement of the thickness, the visualization of the echogenity and echotexture and of the demonstration of focal masses. However, evaluation of the uterine cavity by transvaginal sonography is limited and an abnormal ultrasound of the endometrium may reflect benign or malignant conditions. Furthermore, small structures can be missed or overlooked. If indicated, hydrosonography offers various advantages compared to dilatation and curettage and hysteroscopy in terms of costs, availability and risks. Additional informations obtained after hydrosonography may influence the management before consideration of curettage or hysteroscopy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.