Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website.Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre -including this research content -immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
To assess pulmonary vascular metrics on chest CT of COVID-19 patients, and their correlation with pneumonia extent (PnE) and outcome, we analyzed COVID-19 patients with an available previous chest CT, excluding those performed for cardiovascular disease. From February 21 to March 21, 2020, of 672 suspected COVID-19 patients from two centers who underwent CT, 45 RT-PCR-positives (28 males, median age 75, IQR 66-81 years) with previous CTs performed a median 36 months before (IQR 12-72 months) were included. We assessed PnE, pulmonary artery (PA) diameter, ascending aorta (Ao) diameter, and PA/ Ao ratio. Most common presentations were fever and dyspnea (15/45) and fever alone (13/45). Outcome was available for 41/45 patients, 15/41 dead and 26/41 discharged. Ground-glass opacities (GGOs) alone were found in 29/45 patients, GGOs with consolidations in 15/45, consolidations alone in 1/45. All but one patient had bilateral pneumonia, 9/45 minimal, 22/45 mild, 9/45 moderate, and 5/45 severe PnE. PA diameter (median 31 mm, IQR 28-33 mm) was larger than before (26 mm, IQR 25-29 mm) (P<0.001), PA/ Ao ratio (median 0.83, IQR 0.76-0.92) was higher than before (0.76, IQR 0.72-0.82) (P<0.001). Patients with adverse outcome (death) had higher PA diameter (P=0.001), compared to discharged ones. Only weak correlations were found between ΔPA or ΔPA/Ao and PnE (ρ≤0.453, P≤0.032), with 4/45 cases with moderatesevere PnE and minimal increase in PA metrics. In conclusion, enlarged PA diameter was associated to death in COVID-19 patients, a finding deserving further investigation as a potential driver of therapy decisionmaking.
Multicentre multi-specialty use of the CGuard EPS in routine clinical practice was associated with no major periprocedural neurologic complications and a total elimination of post-procedural neurologic complications by 30 days.
Pulmonary parenchymal and vascular damage are frequently reported in COVID-19 patients and can be assessed with unenhanced chest computed tomography (CT), widely used as a triaging exam. Integrating clinical data, chest CT features, and CT-derived vascular metrics, we aimed to build a predictive model of in-hospital mortality using univariate analysis (Mann–Whitney U test) and machine learning models (support vectors machines (SVM) and multilayer perceptrons (MLP)). Patients with RT-PCR-confirmed SARS-CoV-2 infection and unenhanced chest CT performed on emergency department admission were included after retrieving their outcome (discharge or death), with an 85/15% training/test dataset split. Out of 897 patients, the 229 (26%) patients who died during hospitalization had higher median pulmonary artery diameter (29.0 mm) than patients who survived (27.0 mm, p < 0.001) and higher median ascending aortic diameter (36.6 mm versus 34.0 mm, p < 0.001). SVM and MLP best models considered the same ten input features, yielding a 0.747 (precision 0.522, recall 0.800) and 0.844 (precision 0.680, recall 0.567) area under the curve, respectively. In this model integrating clinical and radiological data, pulmonary artery diameter was the third most important predictor after age and parenchymal involvement extent, contributing to reliable in-hospital mortality prediction, highlighting the value of vascular metrics in improving patient stratification.
This is the first prospective trial investigating the safety and efficacy of vacuum assisted thrombo-aspiration systems in patients with acute lower limb ischaemia in a controlled setting. Results of this investigation give more evidence for a shift of treatment recommendation towards endovascular options in patients with acute lower limb ischaemia, as already suggested by the recent European Society for Vascular Surgery/European Society for Cardiology guidelines.Objective: The aim was to evaluate the short term safety and effectiveness of the Penumbra/Indigo aspiration thrombectomy Systems (Penumbra Inc.) in patients with acute lower limb ischaemia. (ALLI). Recently, endovascular vacuum assisted thrombectomy devices, similar to those used in the management of acute ischaemic stroke, have become available for peripheral arteries, but data are still scarce. Methods: To assess vessel patency, a modified Thrombolysis in Myocardial Infarction (TIMI) classification, called TIPI (Thrombo-aspiration In Peripheral Ischaemia), is proposed. The TIPI flow is assessed at presentation, immediately after treatment with the study device, and after all adjuvant procedures. The primary outcome is the technical success of the thrombo-aspiration with the investigative system, defined as near complete or complete revascularisation TIPI 2 e 3. Safety and clinical success rate were collected at one month. Results: One hundred and fifty patients were enrolled. The mean age was 72.4 years and 73.3% were male. Rutherford grade on enrolment was I in 16%, IIa in 40.7%, and IIb in 43.3% with a mean ankle brachial index of 0.19. Primary technical success (TIPI 2 e 3 flow) was achieved in 88.7% of patients. Adjunctive procedures included angioplasty/stenting of chronic atherosclerotic lesions (n ¼ 39), thrombolysis (n ¼ 31), covered stenting (n ¼ 15), and supplementary Fogarty embolectomy (n ¼ 6). After all interventions, assisted primary technical success was 95.3% (TIPI 2 e 3 in 143/150). No systemic bleeding complications or device related serious adverse events were reported. At one month follow up, one death, and one below the knee amputation were recorded. Primary patency was 92% (138/150), and the re-intervention rate was 7.33%, resulting in an assisted primary and secondary patency of 94% and 99.33%, respectively. Conclusion: Results from the INDIAN registry reveal that mechanical thrombectomy using the Indigo system is safe and effective for revascularisation of ALLI as a primary therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.