The Moon’s environmental conditions present limited opportunities for waste heat dissipation, so internal heat gains (IHG) are a key component of thermal balance in a lunar building. Despite the significant development in energy saving and energy storage technologies of the last thirty years, the issue of IHG in lunar buildings has not been readdressed since the early 1990s. This study is based on an inspection of internal heat sources conducted aboard LUNARES, the first European extraterrestrial analogue habitat. The equipment absent on LUNARES, but indispensable for an actual lunar base, was identified and accounted for, along with additional laboratory and maintenance equipment. Three main groups of internal heat sources were identified and studied in detail. Waste heat generated by electric devices was accounted for, along with occupational heat loads adjusted for lunar partial gravity conditions. Assuming a photovoltaic power source for the studied building, two alternative energy storage systems (ESS) were analysed as another source of waste heat. Depending on the time of lunar day and applied ESS, the nominal IHG were between 73 and 133 W/m2. The most significant internal heat sources in a lunar base are life support systems and potentially, regenerative fuel cells; thus, lithium–ion batteries were recommended for ESS. Within assumed parameter range, parametric study exhibited differences in IHG between 41.5 and 163 W/m2.
The article presents a comparative analysis carried out using three methods, determining the heat transfer coefficient U for a ceramic product modified with a phase change material (PCM). The purpose of the article is to determine the convergence of the resulting thermal characteristics, obtained using the experimental method, numerical simulation, and standard calculation method according to the requirements of PN-EN ISO 6946. The heat transfer coefficient is one of the basic parameters characterizing the thermal insulation of a building partition. Most often, for the thermal characteristics of the partition, we obtain from the manufacturer the value of the thermal conductivity coefficient λ for individual homogeneous materials or the heat transfer coefficient U for the finished (prefabricated) partition. In the case of a designed composite element modified with a phase change material or other material, it is not possible to obtain direct information on the above parameter. In such a case, one of the methods presented in this article should be used to determine the U factor. The U factor in all analyses was determined in stationary conditions. Research has shown a significant convergence of the resulting value of the heat transfer coefficient obtained by the assumed methods. Thanks to obtaining similar values, it is possible to continue tests of thermal characteristics of partitions by means of numerical simulation, limiting the number of experimental tests (due to the longer test time required) in assumed different partition configurations, in stationary and dynamic conditions.
The article presents the concept of improving the thermal insulation properties of a window thanks to the installation of an additional internal window. The resulting quasi-box window can be an alternative to the thermo-modernization of windows by replacing them. Measurements of the thermal parameters of the prototype and the unmodified window were made in an office space during its standard use. A quantitative and qualitative analysis of the compared solutions was made.
The article presents four equivalent methods for checking mold growth on the surface of building barriers and checking water vapor condensation on their surface. Each method applies to two parallel phenomena that may occur on a building barrier. The first method is to calculate and compare temperature factors. In the second method, the characteristic humidity in the room is calculated and compared. The third method is to calculate and compare the characteristic temperatures in the room. The fourth method is based on the calculation and comparison of characteristic water vapor pressures. Three boundary conditions are presented for each method and phenomenon: when a given phenomenon can occur, when it begins or ends, and when it does not occur. The presented methods systematize the approach to the problem of mold development and surface condensation. The presented calculation results relate to the selected building barrier functioning in specific indoor and outdoor climate conditions. The calculation results confirm the compliance of the presented methods in identifying the phenomenon of mold growth or condensation on the surface of the barrier. A graphical interpretation of the results for each method with periods of occurrence or absence of a given phenomenon is also presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.