Splanchnic mucosal perfusion abnormalities have been implicated in the development of sepsis and multiorgan failure. We employed reflectance spectrophotometry for direct assessment of the microvascular hemoglobin oxygen saturation (HbiO2) and hemoglobin concentration (rel Hb(conc)) in the mucosa of the upper gastrointestinal tract. Owing to the high recording frequency together with a small catchment volume, assessment of spatial heterogeneity is enabled. Results were as follows: In healthy controls (n = 7), mean HbiO2 was 70.3 +/- 2.1%, with narrow dispersion and near-Gaussian distribution of the histogram. In patients presenting with hyperdynamic septic shock (n = 15) mean HbiO2 was reduced to 51.0 +/- 1.6% in spite of high normal whole-body oxygen delivery, with tailing of the histogram to severely hypoxic values (18.4 % of data < 40%). In parallel, markedly reduced rel Hb(conc) values were recorded and the standardized intramucosal pH (pHi) was lowered to 7.25 +/- 0.01. Short-term infusion of dopexamine (2 microg/kg/min) caused a significant rise in HbiO2 and rel Hb(conc), whereas whole-body oxygen uptake and standardized pHi values were not altered. In conclusion, decreased oxygenation and tissue hemoglobin concentration, with the appearance of severely hypoxic microdomains, were noted in patients with hyperdynamic sepsis, strongly suggesting pronounced microcirculatory disturbances in this compartment. The partial responsiveness of these abnormalities to dopexamine warrants further elucidation.
Buffered electrolyte solutions are preferable to saline for achieving reliable pCO2 measurements in gastric tonometry. Air-filled balloons, combined with automated capnometry, present excellent accuracy and reproducibility together with short equilibration times, thus offering "on-line" monitoring of even rapid changes in environmental pCO2.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.